A comparative study of nozzle/diffuser micropumps with novel valves.

نویسندگان

  • Kai-Shing Yang
  • Tzu-Feng Chao
  • Ing Youn Chen
  • Chi-Chuan Wang
  • Jin-Cherng Shyu
چکیده

This study conducts an experimental study concerning the improvement of nozzle/diffuser micropump design using some novel no-moving-part valves. A total of three micropumps, including two enhancement structures having two-fin or obstacle structure and one conventional micro nozzle/diffuser design, are made and tested in this study. It is found that dramatic increase of the pressure drops across the designed micro nozzles/diffusers are seen when the obstacle or fin structure is added. The resultant maximum flow rates are 47.07 mm³/s and 53.39 mm³/s, respectively, for the conventional micro nozzle/diffuser and the added two-fin structure in micro nozzle/diffuser operated at a frequency of 400 Hz. Yet the mass flow rate for two-fin design surpasses that of conventional one when the frequency is below 425 Hz but the trend is reversed with a further increase of frequency. This is because the maximum efficiency ratio improvement for added two-fin is appreciably higher than the other design at a lower operating frequency. In the meantime, despite the efficiency ratio of the obstacle structure also reveals a similar trend as that of two-fin design, its significant pressure drop (flow resistance) had offset its superiority at low operating frequency, thereby leading to a lesser flow rate throughout the test range.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design and Fabrication of MEMS Micropumps using Double Sided Etching

In this paper, we report a simple technique for the fabrication of planar valveless micropumps. The technique utilizes MEMS fabrication methods by using a double sided etch technique. Instead of using several masks and process steps, an anisotropic wet etch technique at both sides of a silicon substrate is implemented at the same time for creating the pump membrane and the diffuser/ nozzle elem...

متن کامل

Low Reynolds Number Flow Through Nozzle-Diffuser Elements in Valveless Micropumps

Flow characteristics of low Reynolds number laminar flow through gradually expanding conical and planar diffusers were investigated. Such diffusers are used in valveless micropumps to effect flow rectification and thus lead to pumping action in one preferential direction. Four different types of diffuser flows are considered: fully developed and thin inlet boundary layer flows through conical a...

متن کامل

Design and Simulation of Valve Less PZT Micropump for Drug Delivery System

In this paper some discrete parts of an electrostatic and flat-walled self-aligned valveless, micropump for drug delivery system is designed and simulated. The core component of the system is a piezoelectric diaphragm that can convert the reciprocating movement of a diaphragm actuated by a piezoelectric actuator into a pumping effect. The deflection in the diaphragm was analyzed by applying the...

متن کامل

Simulation-based Analysis of 3d Flow inside a Micropump with Passive Valves

It is expected that chemical, biological and environmental applications of microdevices will increase with new developments in micromachining techniques. In this work, a micropump design that utilizes passive valves and an actuated diaphragm is presented. The flow rate is controlled by the deflection and the frequency of the diaphragm’s displacement. Passive valves are used for directing the fl...

متن کامل

Motion of a droplet through microfluidic ratchets.

We report numerical and experimental studies on a droplet moving through an array of mirofluidic ratchets. Droplets are formed at a T junction and subsequently forced through microfluidic ratchets in the form of diffuser/nozzle structures. At the same flow rates of the continuous and the dispersed phases, the velocity of the droplet is determined by the viscosity of the continuous phase and the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Molecules

دوره 17 2  شماره 

صفحات  -

تاریخ انتشار 2012