The validity of determining the hydrogel lens thickness from the swell factor.

نویسندگان

  • D F Loran
  • C N French
  • D Auerbach
چکیده

It is well established that the thickness of a hydrogel contact lens is a significant parameter both in terms of fitting (Mertz et al., 1979; Killpatrick, 1980) and oxygen transmissibility (Hill, 1975). It is acknowledged that the average thickness is clinically significant with respect to gas transmission and the edge thickness relates primarily to comfort and peripheral corneal anoxia. In practice however one is generally concerned with the centre thickness, because it is more easily measured and can be checked in air using a conventional radiuscope (Harris et al., 1973; Paramore and Wechsler, 1979; Wechsler and Paramore, 1978). A tolerance better than ± 0.05 mm (wet) as recommended by the British Standards Institute (BSI) in 1978 may readily be achieved (see Table 1).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigation of Swelling Behavior and Mechanical Properties of a pH-Sensitive Superporous Hydrogel Composite

   The objective of the present study is to develop and investigate the swelling behavior of pH-sensitive Superporous Hydrogel (SPH) and SPH composite (SPHC). A novel superporous hydrogel containing poly (methacrylic acid-co-acrylamide) was synthesized from methacrylic acid and acrylamide through the aqueous solution polymerization, using N,N-methylenebisacrylamide as a crosslinker and ammonium...

متن کامل

Investigation of Swelling Behavior and Mechanical Properties of a pH-Sensitive Superporous Hydrogel Composite

   The objective of the present study is to develop and investigate the swelling behavior of pH-sensitive Superporous Hydrogel (SPH) and SPH composite (SPHC). A novel superporous hydrogel containing poly (methacrylic acid-co-acrylamide) was synthesized from methacrylic acid and acrylamide through the aqueous solution polymerization, using N,N-methylenebisacrylamide as a crosslinker and ammonium...

متن کامل

Effect of surface tension on swell-induced surface instability of substrate-confined hydrogel layers†

Swell-induced surface instability has been observed experimentally in rubbers and gels. Here we present a theoretical model that predicts the critical condition along with a characteristic wavelength for swellinduced surface instability in substrate-confined hydrogel layers. The effect of surface tension is found to be critical in suppressing short-wavelength modes of instability, while the sub...

متن کامل

The Biometric Values of Affected and Fellow Eyes in Patients with Acute Attack of Primary Angle Closure

Background: It has been estimated that 67 million people worldwide are affected with a primary glaucoma and that one-third have primary angle closure glaucoma. We aimed to determine the biometric differences between the eyes of patients with acute attack of primary angle closure and their non-involved fellow eyes. Methods: Twenty eight patients with acute attack of primary angle closure were re...

متن کامل

Assessing the image quality and eye lens dose reduction using bismuth shielding in computed tomography of brain

Background: Epidemiological studies show that computed tomography (CT) is one of the main sources of ionizing radiations. Shielding of radiosensitive organs is one of the dose reduction methods. This study aimed to assess the eye lens dose reduction and image quality resulting from the use of radio-protective bismuth shield in brain CT imaging. Methods: Bismut...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians

دوره 2 3  شماره 

صفحات  -

تاریخ انتشار 1982