The Effects of Denture Cleansing Solutions on the Retention of Attachments of Implant Supported Overdentures
نویسندگان
چکیده
STATEMENT OF THE PROBLEM Implant-retained overdenture can improve the stability of dentures and prevent bone loss. Overdenture-wearing patients need special hygiene care. PURPOSE The aim of this study was to evaluate the effects of various denture cleansers on the retention of Dio orange O-rings. METHOD AND MATERIALS In this experimental study, 40 Dio orange O-rings were divided into 4 groups (10 O-rings each) and each group was soaked for equivalent of 6 months in the following solutions: 5.25% NaOCl (1:10 dilution), Corega cleanser tabs, Professional cleanser tabs and water (as the control group). After 6 months, O-rings were tested for 2inch/minutes of tensile force. The peak load-to-dislodgement was recorded. Data were imported to SPSS18 and were analyzed by One-Way ANOVA and Tukey HSD test (p≤ 0.05). RESULTS Denture cleansing solutions have significant effects on the reduction of retentive value of O-rings (p≤ 0.001). Corega tabs caused the reduction of 15.7% (9.91±0.53 N) in the retentive value of O-rings and Professional tabs caused 15% (10.00±0.86 N). NaOCl caused significant decrease (48%) in retentive value of O-rings (6.10±0.91 N in comparison with the control group (11.76±1 N). CONCLUSION This in-vitro study demonstrated that the retention of O-rings was affected when soaked in cleansing solutions. NaOCl caused more reduction in retentive value compared to effervescent cleansers and would not be recommended for cleansing O-rings. These results should be interpreted clinically and the role of other factors in the retention of O-rings should be considered in order to recommend the best cleanser for O-ring overdentures.
منابع مشابه
Effect of Denture Cleansing Solutions on Retention of Two Types of Overdenture Attachments
Background and Aim: There is lack of information regarding the effect of different denture cleansing solutions on the retention of attachments. This study aimed to as-sess the effect of denture cleansing solutions on the retention of Dalbo-Plus and Loca-tor attachment systems. Materials and Methods: This study evaluated 160 attachments including 80 Locator and 80 Dalbo-Plus attachment systems....
متن کاملComparison of stresses transferred to the implant supported overdentures with bar, ball and zaag attachments through photoelasticity
Comparison of stresses transferred to the implant supported overdentures with bar, ball and zaag attachments through photoelasticity Dr. A. Saboori* - Dr. Gh. Esfahanizade** - Dr. M. Ejlali*** *- Assistant Professor of Prosthodontics Dept. - Faculty of Dentistry – Shaheed Beheshti University of Medical Sciences. **- Assistant Professor of Prosthodontics Dept. - Faculty of Dentistry – Tehran Isl...
متن کاملComparison of the Effect of Ball and Bar Attachment Designs on Retention and Stability of Mandibular Implant-Supported Overdentures
Objectives: The present study evaluated the effect of bar and ball attachment designs on retention and stability of a mandibular overdenture supported by four implants. Methods: An edentulous mandibular acrylic resin model with four implants in the anterior part of the ridge (A, B, D and E) was fabricated. A metal framework simulating the overdenture was also fabricated. Totally, 30...
متن کاملMaxillary Implant-Supported Over-Denture, Role of Attachment Selection on Treatment Success Rate: A Literature Review
Objectives Maxillary implant-supported over-denture is a suitable treatment where conventional denture cannot be used. Few studies are available on maxillary over-denture while more are available on mandibular over-denture with no literature referring to attachment selection in maxillary over-dentures. The objective of this literature review was to see attachment selection strategies in maxill...
متن کاملEffects of overdenture retention designs and implant orientations on load transfer characteristics.
Various approaches have been used for the retention and stabilization of implant-supported overdentures. This study examined photoelastically the simulated load transfer characteristics of a resilient cap attachment with moderately atrophied mandibular plastic models with two implant orientations. Comparison was made with overdentures supported by a splinting bar and a bar with distal resilient...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 16 شماره
صفحات -
تاریخ انتشار 2015