Can Dental Cone Beam Computed Tomography Assess Bone Mineral Density?

نویسنده

  • Do-Gyoon Kim
چکیده

Mineral density distribution of bone tissue is altered by active bone modeling and remodeling due to bone complications including bone disease and implantation surgery. Clinical cone beam computed tomography (CBCT) has been examined whether it can assess oral bone mineral density (BMD) in patient. It has been indicated that CBCT has disadvantages of higher noise and lower contrast than conventional medical computed tomography (CT) systems. On the other hand, it has advantages of a relatively lower cost and radiation dose but higher spatial resolution. However, the reliability of CBCT based mineral density measurement has not yet been fully validated. Thus, the objectives of this review are to discuss 1) why assessment of BMD distribution is important and 2) whether the clinical CBCT can be used as a potential tool to measure the BMD. Brief descriptions of image artefacts associated with assessment of gray value, which has been used to account for mineral density, in CBCT images are provided. Techniques to correct local and conversion errors in obtaining the gray values in CBCT images are also introduced. This review can be used as a quick reference for users who may encounter these errors during analysis of CBCT images.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی رابطه بین دانسیته استخوانی حاصل ازCone-Beam Computed Tomography با میزان ثبات اولیه ایمپلنت دندانی

Introduction & Objective: Study of bone quality before treatment is very important. The aims of this study were to assess bone quality with density values obtained by cone-beam computed tomography (CBCT) and to determine the correlations between bone density and primary stability of dental implants. Materials & Methods: In this experimental in vitro study 32 implants were inserted into fresh ...

متن کامل

Correlation Between Tissue Densities in Computed Tomography and Three Different Cone-Beam Computed Tomography Units (In Vitro)

Background and Aim: Bone density is of great assistance in the selection of the proper implant site. The present study aimed to assess the correlation between tissue densities in computed tomography (CT) and three different cone-beam computed tomography (CBCT) units. Materials and Methods: In this descriptive study, a radiographic phantom consisting of a transparent polymethyl methacrylate (PM...

متن کامل

بررسی تأثیر دو دسته داروی کنترل فشارخون بر تراکم استخوان فکین در مردان بالای 50 سال شهر یزد با استفاده از Cone-Beam Computed Tomography در سال 1394

Introduction: Aging increases the probability of the concurrent incidence of osteoporosis and hypertension. It is demonstrated that antihypertensive drugs can affect bone metabolism. The object of this study was to evaluate the effects of antihypertensive medication on bone mineral density of maxilla and mandible in males over 50 years old using CBCT. Methods: In this analytical cross-sectio...

متن کامل

A comparative evaluation of cone-beam computed tomography and multi-slice computed tomography in the diagnosis of sheep mandibular bone defect: an in vitro study

Introduction: Diagnosis of lesions and bone defects is very important and there is a lack of substantial studies on the most appropriate method for bone defect measurement. Hence, the aim of this study is to evaluate the accuracy of multi-slice computed tomography (MSCT) and cone-beam computed tomography (CBCT) in the diagnosis of mandibular bone defects present in sheep. Material & Methods: T...

متن کامل

Measuring the thickness of buccal cortical bone of maxillary premolar teeth by cone beam computed tomography technique

Background and Aims: Immediate implant placement following tooth extraction is a treatment with many advantages. Alveolar bone preservation after immediate implant, need minimum of 2 mm thickness in buccal bone plate. The aim of this study was to evaluate the thickness of buccal cortical bone of maxillary premolars by Cone Beam Computational Tomography (CBCT) technique. Materials and Methods: ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 21  شماره 

صفحات  -

تاریخ انتشار 2014