Using flow information to support 3D vessel reconstruction from rotational angiography.
نویسندگان
چکیده
For the assessment of cerebrovascular diseases, it is beneficial to obtain three-dimensional (3D) morphologic and hemodynamic information about the vessel system. Rotational angiography is routinely used to image the 3D vascular geometry and we have shown previously that rotational subtraction angiography has the potential to also give quantitative information about blood flow. Flow information can be determined when the angiographic sequence shows inflow and possibly outflow of contrast agent. However, a standard volume reconstruction assumes that the vessel tree is uniformly filled with contrast agent during the whole acquisition. If this is not the case, the reconstruction exhibits artifacts. Here, we show how flow information can be used to support the reconstruction of the 3D vessel centerline and radii in this case. Our method uses the fast marching algorithm to determine the order in which voxels are analyzed. For every voxel, the rotational time intensity curve (R-TIC) is determined from the image intensities at the projection points of the current voxel. Next, the bolus arrival time of the contrast agent at the voxel is estimated from the R-TIC. Then, a measure of the intensity and duration of the enhancement is determined, from which a speed value is calculated that steers the propagation of the fast marching algorithm. The results of the fast marching algorithm are used to determine the 3D centerline by backtracking. The 3D radius is reconstructed from 2D radius estimates on the projection images. The proposed method was tested on computer simulated rotational angiography sequences with systematically varied x-ray acquisition, blood flow, and contrast agent injection parameters and on datasets from an experimental setup using an anthropomorphic cerebrovascular phantom. For the computer simulation, the mean absolute error of the 3D centerline and 3D radius estimation was 0.42 and 0.25 mm, respectively. For the experimental datasets, the mean absolute error of the 3D centerline was 0.45 mm. Under pulsatile and nonpulsatile conditions, flow information can be used to enable a 3D vessel reconstruction from rotational angiography with inflow and possibly outflow of contrast agent. We found that the most important parameter for the quality of the reconstruction of centerline and radii is the range through which the x-ray system rotates in the time span of the injection. Good results were obtained if this range was at least 135 degrees. As a standard c-arm can rotate 205 degrees, typically one third of the acquisition can show inflow or outflow of contrast agent, which is required for the quantification of blood flow from rotational angiography.
منابع مشابه
3D Reconstruction of Cerebral Blood Flow and Vessel Morphology from X-Ray Rotational Angiography
Three-dimensional (3D) information on blood flow and vessel morphology is important when assessing cerebrovascular disease and when monitoring interventions. Rotational angiography is nowadays routinely used to determine the geometry of the cerebral vasculature. To this end, contrast agent is injected into one of the supplying arteries and the x-ray system rotates around the head of the patient...
متن کاملThree-dimensional fusion digital subtraction angiography: new reconstruction algorithm for simultaneous three-dimensional rendering of osseous and vascular information obtained during rotational angiography.
This report describes three-dimensional (3D) fusion digital subtraction angiography (FDSA), a new algorithm for rotational angiography that combines reconstructions of the blood vessels and the osseous frame in a single 3D representation. 3D-FDSA is based on separate reconstructions of the mask and contrast sequences of the rotational acquisition. The two independent 3D data sets (3D-bone and 3...
متن کاملTargeted ROTational magnetic resonance angiography (TROTA).
An MR angiographic method is presented in which a rotating 2D slice is centered on and targets a region or vessel of interest. Collecting a series of slices rotating about the center of the targeted region yields projection data sufficient for the calculation of 3D volumetric data of the region using conventional backprojection reconstruction techniques. These volumetric data depict the interna...
متن کاملThree-dimensional coronary sinus reconstruction-guided left ventricular lead implantation based on intraprocedural rotational angiography: a novel imaging modality in cardiac resynchronization device implantation.
AIMS Rotational angiography (RA) of the coronary sinus (CS) provides more anatomical insights compared with static angiographies. We evaluated intraprocedural three-dimensional (3D) CS reconstruction (RC) based on RA, using syngo(®) DynaCT Cardiac to guide CS lead implantation. METHODS AND RESULTS In 24 patients with indication for cardiac resynchronization therapy, intraprocedural RA and 3D ...
متن کامل3D Reconstruction of Stenotic Coronary Arterial Segments using Intravascular Ultrasound and Angiographic Images
A number of imaging modalities help in the diagnosis of coronary artery disease. Intravascular ultrasound (IVUS) and biplane coronary angiography represent commonly used diagnostic tools. IVUS imaging generates cross sectional images of the vessel and permits direct visualization of the morphology of coronary arteries. This information is important for the diagnosis of coronary artery disease a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Medical physics
دوره 35 7Part1 شماره
صفحات -
تاریخ انتشار 2008