Comparison of the Effects of Bare Metal Stents and Drug Eluting Stents on C- Reactive Protein Levels
نویسندگان
چکیده
Aim: It’s suggested that drug eluting stents (DES) may have systemic anti inflammatory properties and this can play a role in decreased restenosis rates. We aimed to compare bare metal stents (BMS) and DES on their effects on C-reactive protein (CRP) levels, a good marker of systemic inflammation. We also aimed to investigate the relation between the inflammation levels and myonecrosis and adverse cardiac events. Methods: Patients undergoing elective stent implantation were grouped as BMS (n = 70) and DES (n = 42). Basal and 24th hour postprocedural CRP and CKMB levels were measured and the difference (Δ) was compared between the groups. The patients were followed up for adverse cardiac events for one year. Results: Mean age was 62 ± 11 and 75% were males. There was significant CRP rise in both groups at 24th hour, the ΔCRP was 2.1 (0.5-6.2) mg/L in BMS and 2.3 (0.25.2) mg/L in DES group, the difference wasn’t statistically significant (p = 0.703). ΔCKMB and adverse cardiac event rates were similar between the two groups (p = 0.897 and p = 0.785). There was no correlation between ΔCRP and ΔCKMB (r = -0.090 and p = 0.459 for BMS, r = 0.158 and p = 0.318 for DES). The effect of ΔCRP on the incidence of adverse cardiac events was not significant (p = 0.349 for BMS, p = 0.135 for DES). Conclusion: Our findings reveal that patients with BMS and DES implantation exhibit similar grade of systemic inflammation after the procedure. At similar levels of systemic inflammation, the local anti inflammatory properties of DES can play a role at decreased restenosis rates. Received Date: September 23, 2015 Accepted Date: December 18, 2015 Published Date: December 27, 2015 Citation: Ozyuncu, N., et al. Recent Advances in Management of Anti-Coagulation in Atrial Fibrillation. (2015) J Heart Cardiol 1(3): 1-7.
منابع مشابه
Outcomes with various drug eluting or bare metal stents in patients with diabetes mellitus: mixed treatment comparison analysis of 22 844 patient years of follow-up from randomised trials
OBJECTIVES To evaluate the efficacy and safety of currently used drug eluting stents compared with each other and compared with bare metal stents in patients with diabetes. DESIGN Mixed treatment comparison meta-analysis. DATA SOURCES AND STUDY SELECTION PubMed, Embase, and CENTRAL were searched for randomised clinical trials, until April 2012, of four durable polymer drug eluting stents (s...
متن کاملA comparison of bare-metal and drug-eluting stents for off-label indications.
BACKGROUND Recent reports suggest that off-label use of drug-eluting stents is associated with an increased incidence of adverse events. Whether the use of bare-metal stents would yield different results is unknown. METHODS We analyzed data from 6551 patients in the National Heart, Lung, and Blood Institute Dynamic Registry according to whether they were treated with drug-eluting stents or ba...
متن کاملDrug-Eluting or Bare-Metal Stents for Coronary Artery Disease.
BACKGROUND Limited data are available on the long-term effects of contemporary drug-eluting stents versus contemporary bare-metal stents on rates of death, myocardial infarction, repeat revascularization, and stent thrombosis and on quality of life. METHODS We randomly assigned 9013 patients who had stable or unstable coronary artery disease to undergo percutaneous coronary intervention (PCI)...
متن کاملDrug-eluting versus bare-metal stents in large coronary arteries.
BACKGROUND Recent data have suggested that patients with coronary disease in large arteries are at increased risk for late cardiac events after percutaneous intervention with first-generation drug-eluting stents, as compared with bare-metal stents. We sought to confirm this observation and to assess whether this increase in risk was also seen with second-generation drug-eluting stents. METHOD...
متن کاملBare metal stents, durable polymer drug eluting stents, and biodegradable polymer drug eluting stents for coronary artery disease: mixed treatment comparison meta-analysis
OBJECTIVE To compare the efficacy and safety of biodegradable polymer drug eluting stents with those of bare metal stents and durable polymer drug eluting stents. DESIGN Mixed treatment comparison meta-analysis of 258,544 patient years of follow-up from randomized trials. DATA SOURCES AND STUDY SELECTION PubMed, Embase, and Central were searched for randomized trials comparing any of the Fo...
متن کامل