Predictive value of rotational thromboelastometry during cardiopulmonary bypass for thrombocytopenia and hypofibrinogenemia after weaning of cardiopulmonary bypass

نویسندگان

  • Sung-Mi Ji
  • Sung-Hoon Kim
  • Jae-Sik Nam
  • Hye-Joo Yun
  • Jeong-Hyun Choi
  • Eun-Ho Lee
  • In-Cheol Choi
چکیده

BACKGROUND The early detection of coagulopathy helps guide decisions regarding optimal transfusion management during cardiac surgery. This study aimed to determine whether rotational thromboelastometry (ROTEM) analysis during cardiopulmonary bypass (CPB) could predict thrombocytopenia and hypofibrinogenemia after CPB. METHODS We analyzed 138 cardiac surgical patients for whom ROTEM tests and conventional laboratory tests were performed simultaneously both during and after CPB. An extrinsically activated ROTEM test (EXTEM), a fibrin-specific ROTEM test (FIBTEM) and PLTEM calculated by subtracting FIBTEM from EXTEM were evaluated. Correlations between clot amplitude at 10 min (A10), maximal clot firmness, platelet count, and fibrinogen concentrations at each time point were calculated. A receiver operating characteristic analysis with area under the curve (AUC) was used to assess the thresholds of EXTEM, PLTEM and FIBTEM parameters during CPB and for predicting thrombocytopenia and hypofibrinogenemia after weaning of CPB. RESULTS The A10 on EXTEM, PLTEM, and FIBTEM during CPB showed a good correlation with platelet counts (r = 0.622 on EXTEM and r = 0.637 on PLTEM; P < 0.0001 for each value) and fibrinogen levels (r = 0.780; P < 0.0001) after CPB. A10 on a FIBTEM threshold of 8 mm during the CPB predicted a fibrinogen concentration < 150 mg/dl (AUC = 0.853) after CPB. Additionally, the threshold level of A10 on EXTEM during CPB for predicting platelet counts < 100,000 /µl after CPB was 42 mm (AUC = 0.768). CONCLUSIONS EXTEM, PLTEM, and FIBTEM parameters during CPB may be useful for predicting thrombocytopenia and hypofibrinogenemia after weaning of CPB.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Coagulopathies in Cyanotic Cardiac Patients: An Analysis with Three Point-of-care Testing Devices (Thromboelastography, Rotational Thromboelastometry, and Sonoclot Analyzer)

INTRODUCTION In the last few years, viscoelastic point-of-care (POC) coagulation devices such as thromboelastography (TEG), rotational thromboelastometry (ROTEM), and Sonoclot (SON) analyzer have been increasingly used in major surgeries for timely assessment and management of coagulopathies. The aim of the present study was to evaluate coagulation profile of cyanotic cardiac patients with TEG,...

متن کامل

Fresh Frozen Plasma in Pump Priming for Congenital Heart Surgery: Evaluation of Effects on Postoperative Coagulation Profiles Using a Fibrinogen Assay and Rotational Thromboelastometry

PURPOSE In this prospective study, the effects of fresh frozen plasma (FFP) included in pump priming for congenital heart surgery in infants and children on post-bypass coagulation profiles were evaluated. MATERIALS AND METHODS Either 20% albumin (50-100 mL) or FFP (1-2 units) was added to pump priming for patients randomly allocated into control or treatment groups, respectively. Hematologic...

متن کامل

Fibrin-based clot firmness as assessed by rotational thromboelastometry is predictor of total amount of chest tube output in patients following elective cardiac surgery

Background Excessive bleeding after cardiopulmonary bypass (CPB) is risk factor for adverse outcomes after elective cardiac surgery (ECS). Differentiation between patients who bleed due to surgical issues and those whose excessive chest tube output (CTO) is due to hemostatic disorder remains challenging. Study aim was to evaluate prediction of excessive bleeding after ECS using fibrin-based clo...

متن کامل

Comparison of the Effect of Voluven and Ringer Solution in Cardiopulmonary Bypass on the Bleeding After the Surgery and Renal Function in Coronary Artery Bypass Graft Surgeries

Background: This study compared the effect of Voluven and Ringer solution in cardiopulmonary bypass on the bleeding after the surgery and renal function in coronary artery bypass graft surgeries. Methods: Two types of prime solution including ringer - as Crystalloid- and Voluven were used in two groups and compared in terms of bleeding and renal function during the first 24 hours after the surg...

متن کامل

End-tidal CO2 for prediction of cardiac output following weaning from cardiopulmonary bypass.

This prospective study included 32 patients undergoing cardiopulmonary bypass (CPB) for elective coronary artery bypass grafting correlates the respiratory end-tidal CO2 (ETCO2) during partial separation from CPB with cardiac output (CO) following weaning from CPB. After induction of general anesthesia, a pulmonary artery catheter was inserted for measurement of cardiac output by thermodilution...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 68  شماره 

صفحات  -

تاریخ انتشار 2015