[Validation of a glucose meter at an intensive care unit].

نویسندگان

  • Miguel Ángel Castaño López
  • José Luís Fernández de Liger Serrano
  • José Luís Robles Rodríguez
  • Tomas Márquez Márquez
چکیده

INTRODUCTION Hyperglycemic patients admitted to Intensive care units (ICUs) have higher morbidity and mortality than normoglycemic patients. Blood glucose levels of ICU patients are usually measured with a glucose meter. The aim of this study was to evaluate a glucose meter (StatStrip, Nova Biomedical) to assess its agreement with the standard laboratory method for testing glucose. MATERIAL AND METHODS Eighty-nine different samples were collected from patients (76.4% men and 23.6% women) admitted to an ICU from September to December 2010. Each blood sample was collected into two tubes, a lithium heparin tube and an EDTA tube. The total blood aliquot was used to measure glycemia using the glucose meter. The lithium heparin tube was processed at the same time for measuring plasma glucose (Cobas 6000 Analyzer, Roche Diagnostics, SA). Agreement between the two methods was assessed according to the EP-9-A2 Clinical Laboratory Standards Institute guideline. RESULTS Mean whole blood glucose level measured by the glucose meter was 126.53+49.28 mg/dL (range, 33.5-431 mg/dL), while mean plasma glucose value measured by the laboratory reference method was 138.13+78.6 mg/dL (range, 43-451 mg/dL). Correlation coefficient was 0.99, with a 95% confidence interval of 0.98 to 0.99. Coefficient of determination (R2) was 0.97, and intraclass correlation coefficient was 0.99 with a 95% CI of 0.98 to 0.99. CONCLUSIONS The tested glucose meter (StatStrip) shows a good linear association, precision, and accuracy when compared to the laboratory reference method. This device is adequate for glucose monitoring.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Screening for hypoglycemia at the bedside in the neonatal intensive care unit (NICU) with the Abbott PCx glucose meter

BACKGROUND Point of care (POC) glucose meters are routinely used as a screening tool for hypoglycemia in a neonatal setting. Glucose meters however, lack the same accuracy as laboratory instruments for glucose measurement. In this study we investigated potential reasons for this inaccuracy and established a cut off value for confirmatory testing. METHODS In this prospective study, all patient...

متن کامل

Analytic evaluation of a new glucose meter system in 15 different critical care settings.

BACKGROUND Maintaining appropriate glycemic control in critically ill patients reduces morbidity and mortality. The use of point-of-care (POC) glucose devices is necessary to obtain rapid results at the patient's bedside. However, the devices should be thoroughly tested in the intended population before implementation. The use of POC glucose meters in critically ill patients has been questioned...

متن کامل

Psychometrics and Validation of the Intensive Care Unit Memory Assessment Tool in the Iranian Population

Background: The intensive care unit memory (ICUM) assessment tool is a practical tool for memory monitoring after the discharge from ICU. Objectives: This psychometric study purported to validate ICUM for a sample population of Iranian patients hospitalized in ICU. Materials & Methods: This research was a descriptive-analytical study that was conducted at Ahvaz University of Medical Scienc...

متن کامل

Analysis: New point-of-care blood glucose monitoring system for the hospital demonstrates satisfactory analytical accuracy using blood from critically ill patients--an important step toward improved blood glucose control in the hospital.

Patients managed in the intensive care units (ICUs) and general wards of the hospital experience a high incidence of hyperglycemia, hypoglycemia, and glycemic variability, despite significant hospital resources devoted to glucose control. Optimized glucose meters and monitoring systems are required to improve the safety and efficacy of insulin delivery and glucose control in the hospital. Safe ...

متن کامل

Glucose Meter Use in the Intensive Care Unit: Much Ado About Something

Glucose meters are a fast and convenient way to measure circulating blood glucose. Like many technologies in healthcare, the use of glucose meters within the hospital has evolved significantly over the last few decades. This change has been driven predominantly by changes in the approach to glycemic control for critically ill patients. Both glycemic control in the intensive care unit (ICU), and...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Endocrinologia y nutricion : organo de la Sociedad Espanola de Endocrinologia y Nutricion

دوره 59 1  شماره 

صفحات  -

تاریخ انتشار 2012