PURPOSE To assess a modified slit lamp-simulated oblique flashlight test in the identification of persons with suspected angle closure. METHODS Standard oblique flashlight test (SOFT) and a modified slit lamp-simulated flashlight test (SSFT) were performed on participants identified as primary angle closure suspects and controls from a population-based study. SOFT graded the iris shadow on the nasal iris as shallow, medium, and deep. SSFT measured the length of iris shadow and corneal diameter by a slit lamp graticule eyepiece after standardizing the illumination parallel to the iris plane. RESULTS SOFT yielded sensitivity and specificity of 76.3% and 80.7% for the detection of eyes with two or more quadrants of pigmented trabecular meshwork not observed on static gonioscopy. Proportions of subjects in the "shallow" category increased from 9.6% in Shaffer angle width grade 4 to 82.3% in grade 0 and were 72.1% in those with steep, 56.7% in those with plateau, and 13.9% in those with regular iris profiles. SSFT yielded 84.8% sensitivity and 76.7% specificity using a cutoff of 0.18 for the ratio between iris shadow length and corneal diameter. This ratio was monotonically associated with the axial anterior chamber depth, and it was significantly greater in eyes with Shaffer angle width grade lower than 2 and significantly less in eyes with Shaffer angle width grades 3 and 4. Reproducibility of SSFT was high (paired t-test; P > 0.05). CONCLUSIONS More accurate measurement by controlling illumination and following a more precise method to measure shadow formation may improve the performance characteristics of this test. However, this method does not appear appropriate for community-based screening because of its relatively low specificity.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A new slit lamp-based technique for anterior chamber angle estimation.

PURPOSE To design and test a new noninvasive method for anterior chamber angle (ACA) estimation based on the slit lamp that is accessible to all eye-care professionals. METHODS A new technique (slit lamp anterior chamber estimation [SLACE]) that aims to overcome some of the limitations of the van Herick procedure was designed. The technique, which only requires a slit lamp, was applied to est...

متن کامل

Risk of acute angle-closure glaucoma after diagnostic mydriasis in nonselected subjects: the Rotterdam Study.

PURPOSE To report the prevalence of narrow anterior chamber angles on slit-lamp examination and the incidence of acute angle-closure glaucoma (AACG) after diagnostic mydriasis in nonselected white subjects aged 55 years and over. METHODS Of all subjects in the population-based Rotterdam Study (n = 7983), 6760 participated in the ophthalmologic examination and received both tropicamide 0.5% an...

متن کامل

Noncontact Screening Methods for the Detection of Narrow Anterior Chamber Angles.

PURPOSE Comparing diagnostic accuracy of biomicroscope techniques (van Herick and Smith's tests, evaluating limbal and central anterior chamber depth, respectively) and advanced imaging (Visante OCT and Pentacam) for detection of gonioscopically narrow anterior chamber angles (ACAs). METHODS A total of 78 subjects with narrow or open ACAs underwent four index tests, performed on both eyes by ...

متن کامل

Evaluation of Visual Signs and Symptoms in Patients with Alzheimer's Disease

Background and Objective:Patients with Alzheimer's disease have impaired visual function even in the early stages of the disease. Therefore, the present study aimed to determine the visual signs and symptoms in patients with Alzheimer's disease and compare them with those in the control group. Materials and Methods:This cross-sectional descriptive study was conducted on 19 Alzheimer patients a...

متن کامل

بررسی فراوانی آلودگی میکروبی دستگاه های بیومیکروسکوپ چشمی Slit-lamp موجود در مرکز چشم پزشکی بیمارستان فرشچیان همدان و ارزیابی ضد عفونی کننده های موجود

Background and Objectives: The aim of this study is the evaluation of bacterial contamination of Slit-lamps in Eye Centers of Farshchian Hospital and assessment of the current disinfectants on isolated bacteria from apparatuses. Methods: In a cross-sectional study, 400 samples were collected from different parts of Slit-lamps (200 samples before and 200 samples after disinfection). The samp...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 48 12  شماره 

صفحات  -

تاریخ انتشار 2007