Magnetic resonance image-guided trans-septal puncture in a swine heart.

نویسندگان

  • Aravind Arepally
  • Parag V Karmarkar
  • Clifford Weiss
  • E Rene Rodriguez
  • Robert J Lederman
  • Ergin Atalar
چکیده

PURPOSE To test the feasibility of performing magnetic resonance (MR)-guided trans-septal punctures in the swine heart. MATERIALS AND METHODS All procedures were performed in a 1.5-T MR scanner. A novel, active MR intravascular needle system was utilized for needle tracking and septal punctures. Trans-septal punctures were performed in five swine using electrocardiogram (ECG)-gated high resolution and non-ECG-gated, real-time MR imaging techniques. The intravascular needle was advanced over a guidewire from the femoral vein. Once the needle was in proper position, trans-septal punctures were made. RESULTS Active tracking of the needle traversing the septum was possible. The location of the catheter tip was confirmed using real time gradient recalled echo (GRE). After a confirmatory ventriculogram with gadolinium-DTPA, a 0.014-inch guidewire was advanced into the left atrium and left ventricle. All punctures were made with no change in cardiac rhythm or rate; postmortem analysis was performed on all animals and demonstrated that 18/19 (95%) punctures were directly through the fossa ovalis. CONCLUSION Using only MR guidance and a novel active intravascular needle system, we were able to repeatedly puncture the fossa ovalis in a swine heart from a transfemoral approach, with direct visualization of all components, including the needle, the atria, the fossa ovalis, and the surrounding vasculature.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Real-time MRI guided atrial septal puncture and balloon septostomy in swine.

Cardiac perforation during atrial septal puncture (ASP) might be avoided by improved image guidance. X-ray fluoroscopy (XRF), which guides ASP, visualizes tissue poorly and does not convey depth information. Ultrasound is limited by device shadows and constrained imaging windows. Alternatively, real-time MRI (rtMRI) provides excellent tissue contrast in any orientation and may enable ASP and ba...

متن کامل

Optimal Transseptal Puncture Location for Robot-Assisted Left Atrial Catheter Ablation

BACKGROUND The preferred method of treatment for atrial fibrillation (AF) is by catheter ablation, in which a catheter is guided into the left atrium through a transseptal puncture. However, the transseptal puncture constrains the catheter, thereby limiting its manoeuvrability and increasing the difficulty in reaching various locations in the left atrium. In this paper, we address the problem o...

متن کامل

Dual echo positive contrast bSSFP for real-time visualization of passive devices duringmagnetic resonance guided cardiovascular catheterization

BACKGROUND Cardiovascular magnetic resonance (CMR) guided cardiovascular catheterizations can potentially reduce ionizing radiation exposure and enable new interventions. Commercially available paramagnetic X-Ray devices create a small signal void in CMR images, which is ambiguous and insufficient to guide catheterization procedures. This work aims to improve real-time CMR of off-the-shelf X-Ra...

متن کامل

O-19: A Comparison of Pelvic Magnetic Resonance Imaging, Trans-Vaginal and Trans-Rectal Sonography with Laparoscopic Findings in The Diagnosis of Deep Infiltrating Endometriosis

Background The performance of TVS, TRS and MRI for the diagnosis of DIE have been separately reported in earlier studies. However, the three methods have not been concurrently compared in terms of their overall performance and classified results as per different anatomical locations of DIE lesions in a large study population. This study was an attempt to compare pelvic magnetic resonance imagin...

متن کامل

Tracking planar orientations of active MRI needles.

PURPOSE To determine and track the planar orientation of active interventional devices without using localizing RF microcoils. MATERIALS AND METHODS An image-based tracking method that determines a device's orientation using projection images was developed. An automated and a manual detection scheme were implemented. The method was demonstrated in an in vivo mesocaval puncture procedure in sw...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of magnetic resonance imaging : JMRI

دوره 21 4  شماره 

صفحات  -

تاریخ انتشار 2005