Effect of distal interlock fixation in stable intertrochanteric fractures.
نویسندگان
چکیده
The objective of this study was to evaluate the torsion stiffness of locked and unlocked distal fixation of long cephalomedullary nail constructs, in both a fresh fracture and healed, stable intertrochanteric fracture model. Samples were tested in both internal and external rotation (0±3 Nm) for a duration of 10 cycles. Each femur was tested without instrumentation (intact femur), with instrumentation and no fracture (healed intertrochanteric fracture), and with instrumentation with an osteotomy creating a stable intertrochanteric fracture (fresh fracture). All specimens were instrumented with a long cephalomedullary nail. A distal interlock was placed in the dynamic position in 1 femur, and the other femur of the matched pair was left unlocked. Mean external (ER) and internal (IR) rotation stiffness for intact femurs without instrumentation (ER, 2.1±0.5 Nm/degree; IR, 2.2±0.5 Nm/degree) was statistically stiffer (P<.05 for all) compared with fresh fractured locked (ER, 1.1±0.2 Nm/degree; IR, 1.1±0.3 Nm/degree) and fresh fractured unlocked (ER, 0.9±0.3 Nm/degree; IR, 1.0±0.2 Nm/degree) samples. Similarly, healed locked (ER, 2.5±0.2 Nm/degree; IR, 2.8±0.1 Nm/degree) and healed unlocked (ER, 2.5±0.5 Nm/degree; IR, 2.4±0.3 Nm/degree) samples had statistically higher stiffness compared with fresh fractured treatments. These results suggest that the unlocked distal constructs provide similar torsional strength compared with locked fixation in these models.
منابع مشابه
The effects of distal interlocking screws on torsional stability in three-part intertrochanteric hip fractures
OBJECTIVE Many surgeons currently use long cephomedullary nails for the treatment of intertrochanteric fractures. The optimal indications for deploying distal interlocks are still debatable. This study examined the torsional biomechanical properties of 3-part intertrochanteric femur fractures in a cadaveric bone model using two different distal fixation strategies, an unlocked long cephalomedul...
متن کاملClinical Outcomes of Intramedullary and Extramedullary Fixation in Unstable Intertrochanteric Fractures: A Randomized Clinical Trial
Background: The best method for repairing intertrochanteric fractures is still controversial. The fixation methods includeextramedullary (EM) and intramedullary (IM). Studies that compare IM and EM fixations for unstable hip fractures arerare. In this study, our goal was to compare the efficacy of EM and IM fixation in treatment of unstable intertrochantericfractures.Met...
متن کاملComparison of Intertrochanteric Fracture Fixation with Dynamic Hip Screw and Bipolar Hemiarthroplasty Techniques
Background: At present, there is no consensus on an appropriate treatment modality for intertrochanteric fractures in the elderly with background diseases. The aim of the present study was to compare treatment outcomes of intertrochanteric fractures reduced with dynamic hip screws (DHS) and bipolar hemiarthroplasty in elderly patients with background medical conditions. Methods: In this randomi...
متن کاملDISPLACED- COMMINUTED INTRAARTICULAR FRACTURES OF THE ADULT DISTAL HUMERUS: FUNCTIONAL RESULTS AFTER INTERNAL FIXATION
Background: Intra-articular T- type or Y- type fractures of the distal end of the humerus are relatively rare, and consequently few surgeons will be able to attain extensive experience with the surgical treatment of these injuries. The current emphasis is on operative intervention with rigid internal fixation and early mobilization. Methods: In this prospective and retrospective study, we r...
متن کاملA Pitfall in Fixation of Distal Humeral Fractures with Pre-Contoured Locking Compression Plate
Anatomically precontoured locking plates are intended to facilitate the fixation of articular fractures and particularly those associated with osteoporosis. Fractures of the distal humerus are relatively uncommon injuries where operative intervention can be exceptionally challenging. The distal humeral trochlea provides a very narrow anatomical window through which to pass a fixed-angle locking...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Orthopedics
دوره 36 7 شماره
صفحات -