Visual function-specific perimetry to identify glaucomatous visual loss using three different definitions of visual field abnormality.

نویسندگان

  • Ali Tafreshi
  • Pamela A Sample
  • Jeffrey M Liebmann
  • Christopher A Girkin
  • Linda M Zangwill
  • Robert N Weinreb
  • Maziar Lalezary
  • Lyne Racette
چکیده

PURPOSE To compare the most recent versions of standard automated perimetry (SAP), short-wavelength automated perimetry (SWAP), and frequency-doubling technology (FDT) using three definitions of visual field (VF) abnormality: single-test abnormality, abnormality confirmed by the same test, and abnormality confirmed by a different test. METHODS Data obtained from one eye of each of 174 patients with glaucoma and 164 age-matched healthy control subjects from the Diagnostic Innovations in Glaucoma Study and African Descent and Glaucoma Evaluation Study were included, based on the appearance of the optic disc on stereophotographs. Each participant had two reliable 24-2 SAP-SITA, SWAP-SITA, and Matrix FDT tests. Receiver operating characteristic (ROC) curves were generated for the PSD of each test to equate the tests at 90% and 95% specificity. SAP, SWAP, and FDT were compared under each definition of VF abnormality by assessing the sensitivities, the agreement between tests and the overlap in deficit location at these set specificities. The tests were also compared using the machine-derived PSD. RESULTS At a set specificity of 95%, single-test sensitivities of 30% (SAP), 29% (SWAP), and 28% (FDT) were observed (all P > 0.05). Sensitivities ranged from 24% to 27% (all P > 0.05) when same-test confirmation was used and from 20% to 23% (all P > 0.05) when different-test confirmation was used. SAP/SAP sensitivity was higher than all different-test combinations (all P < 0.05), and SWAP/FDT sensitivity was lower than all same-test combinations (all P < 0.05). CONCLUSIONS Confirming VF abnormality is important and optimal when an abnormal SAP is confirmed by a subsequent SAP or SWAP test.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigating the effects of glaucomatous (POAG) damage on the mVEP parameters

Introduction: Glaucoma is considered as a major cause of irreversible vision loss, worldwide. Glaucoma includes a diverse ophthalmopathies characterized by attenuating the neural and connective tissue segments and eventually progression of specific patterns of visual dysfunction. Currently, perimetry is known as the most accurate diagnostic method in glaucoma and its follow up...

متن کامل

Visual function-specific perimetry for indirect comparison of different ganglion cell populations in glaucoma.

PURPOSE To compare short-wavelength automated perimetry, frequency-doubling technology perimetry, and motion-automated perimetry, each of which assesses different aspects of visual function, in eyes with glaucomatous optic neuropathy and ocular hypertension. METHODS One hundred thirty-six eyes from 136 subjects were evaluated with all three tests as well as with standard automated perimetry. ...

متن کامل

Comparison of visual evoked potentials, automated perimetry and frequency-doubling perimetry in early detection of glaucomatous visual field loss.

The present study compares frequency-doubling perimetry (FDP), automated perimetry (AP) and visual evoked potentials (VEP) for their ability to diagnose early glaucoma. In present study 224 patients of Clinic for Eye Diseases, Clinical Hospital "Sestre Milosrdnice" that had diagnosis of open angle glaucoma and glaucomatous visual field loss proven by automated static perimetry on only one eye w...

متن کامل

Quantification of glaucomatous visual field defects with automated perimetry.

A method to quantify different glaucomatous visual field defects is presented. Three visual field indices are calculated: the short-term fluctuation, the mean defect, and the corrected loss variation. The method was applied to visual fields tested with program JO on the Octopus automated perimeter. The indices of 130 glaucoma suspects and 50 glaucoma patients were compared with 100 normal contr...

متن کامل

Frequency doubling technology perimetry for detection of glaucomatous visual field loss.

PURPOSE To evaluate the ability of frequency doubling technology perimetry to detect early, moderate, and advanced glaucomatous visual field loss. METHODS In a prospective study, frequency doubling technology perimetry (C-20 full threshold) was performed in the right eye of 254 normal control subjects and 230 patients with early (n = 85), moderate (n = 114), or advanced (n = 31) glaucomatous ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 50 3  شماره 

صفحات  -

تاریخ انتشار 2009