Comparison of long-term angiographic follow-up after sirolimus-eluting stent and bare-metal stent implantation.
نویسندگان
چکیده
BACKGROUND The sirolimus-eluting stent (SES) has dramatically reduced the rate of restenosis in comparison to that with the bare-metal stent (BMS). In previous studies, the minimal luminal diameter (MLD) of lesions treated with a BMS was shown to improve from 6 months to 1 year. METHODS To evaluate 6-month and 1-year outcomes, angiographic follow-up data were analyzed for 285 patients (451 lesions) who underwent successful SES implantation compared to follow-up data for 2,561 patients (3,367 lesions) who underwent BMS implantation. RESULTS Angiographic follow-up was performed at 6 months for 396 SES-treated lesions and 2,628 BMS-treated lesions and at 1 year for 322 SES-treated lesions and 1,540 BMS-treated lesions. The 6-month angiographic restenosis rate was significantly lower for SES-treated lesions than for BMS-treated lesions (4.8% vs. 23.4%, p<0.01). From immediately after stent implantation to 6 months, quantitative coronary angiography revealed a significantly larger decrease in MLD of BMS-treated lesions than in MLD of SES-treated lesions (p<0.01). In BMS-treated lesions in which repeat revascularization was not performed at 6 months, MLD increased significantly from 2.08+/-0.63 mm at 6 months to 2.11+/-0.61 mm at 1 year (p<0.01). In SES-treated lesions, however, MLD decreased significantly from 2.55+/-0.56 mm at 6 months to 2.44+/-0.61 mm at 1 year (p<0.05). CONCLUSIONS From 6 months to 1 year, stenosis of BMS-treated lesions regressed, but stenosis of SES-treated lesions progressed.
منابع مشابه
Primary Stenting of Totally Occluded Native Coronary Arteries II (PRISON II): a randomized comparison of bare metal stent implantation with sirolimus-eluting stent implantation for the treatment of total coronary occlusions.
BACKGROUND Sirolimus-eluting stents markedly reduce the risk of restenosis compared with bare metal stents. However, it is not known whether there are differences in effectiveness between bare metal and sirolimus-eluting stents in patients with total coronary occlusions. METHODS AND RESULTS In a prospective, randomized, single-blind, 2-center trial, we enrolled 200 patients with total coronar...
متن کاملComparison of stent graft, sirolimus stent, and bare metal stent implanted in patients with acute coronary syndrome: clinical and angiographic follow-up.
AIM To compare polytetrafluoroethylene stent graft (PTFE) with sirolimus and bare metal stents in reducing in-stent restenosis in native coronary vessels in patients with acute coronary syndrome. METHODS The study included patients who underwent stent implantation in acute coronary syndrome from January 2003 to May 2004. The patients (n=119) were randomized either to stent graft group (n=40),...
متن کاملPersistent inhibition of neointimal hyperplasia after sirolimus-eluting stent implantation: long-term (up to 2 years) clinical, angiographic, and intravascular ultrasound follow-up.
BACKGROUND Early results of sirolimus-eluting stent implantation showed a nearly complete abolition of neointimal hyperplasia. The question remains, however, whether the early promising results will still be evident at long-term follow-up. The objective of our study was to evaluate the efficiency of sirolimus-eluting stent implantation for up to 2 years of follow-up. METHODS AND RESULTS Fifte...
متن کاملEvaluation of the haemodynamic characteristics of drug-eluting stents at implantation and at follow-up.
AIMS The aim of this study was to investigate the physiologic parameters: fractional flow reserve (FFR), hyperaemic trans-stent gradient (HTG), and wall shear stress (WSS) at implantation and at 6-month follow-up in the drug-eluting sirolimus stent and in its bare metal counterpart implanted in pairs within the same patient. METHODS AND RESULTS Twenty patients, accepted for percutaneous coron...
متن کاملComparison of six-month angiographic and three-year outcomes after sirolimus-eluting stent implantation versus brachytherapy for bare metal in-stent restenosis.
To evaluate long-term effectiveness of sirolimus-eluting stent (SES) implantation for diffuse bare metal in-stent restenosis (ISR), we compared 6-month angiographic and long-term (3-year) clinical outcomes of SES implantation and intracoronary brachytherapy (ICBT). SES implantation for diffuse ISR was performed in 120 consecutive patients and their results were compared with those from 240 pati...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Internal medicine
دوره 47 4 شماره
صفحات -
تاریخ انتشار 2008