[Evaluation of efficiency of a semiconductor gamma camera].
نویسندگان
چکیده
We evaluation basic characteristics of a compact type semiconductor gamma camera (eZ-SCOPE AN) of Cadmium Zinc Telluride (CdZnTe). This new compact gamma camera has 256 semiconductors representing the same number of pixels. Each semiconductor is 2 mm square and is located in 16 lines and rows on the surface of the detector. The specific performance characteristics were evaluated in the study referring to NEMA standards; intrinsic energy resolution, intrinsic count rate performance, integral uniformity, system planar sensitivity, system spatial resolusion, and noise to the neighboring pixels. The intrinsic energy resolution measured 5.7% as FWHM. The intrinsic count rete performance ranging from 17 kcps to 1,285 kcps was evaluated, but the highest intrinsic count rate was not observed. Twenty percents count loss was recognized at 1,021 kcps. The integral uniformity was 1.3% with high sensitivity collimator. The system planar sensitivity was 33,330 cpm/MBq with high resolution collimator and 766,767 cpm/MBq with high sensitivity collimator. The system spatial resolution (FWHM) was 2.0 mm and 2.2 mm when the distance between source and collimator was 0 cm and 3 cm respectively.
منابع مشابه
An alternative mathematical modeling of the scintillation camera and framework for performance analysis of gamma-ray positioning algorithms
Introduction: Substantive amount of work has been done in modeling and analyzing the scintillation camera system processes including positioning and image formation. The goal of this work is to develop a framework for analyzing performance of nonlinear positioning methods upon construction of a mathematical model of the system. In this study, the photodetector array counts are ...
متن کاملFeasibility of portable gamma camera imaging in intraoperative radioguided parathyroid adenoma identification
Novel surgical applications include radioguided procedures in parathyroidectomy operations. In order to investigate the feasibility of usage of the portable gamma camera in parathyroidectomy operations; intraoperative radioguided parathyroidectomy operation was performed in three hyperparathyroidism patients with inconclusive preoperative parathyroid scintigraphy results. Intraoperative portabl...
متن کاملAppropriate energy window width for gamma camera [Persian]
Introduction: Scatter radiation is one of the major sources of error in nuclear medicine data processing. Different methods of scatter correction have been introduced in order to improve the quality of data. However the best method is to avoid recording of scatter photons in acquisition. The only difference between scattered and non-scattered photons is the energy. Pulse height analyzer i...
متن کاملDetermination of virtual point for HPGe detector at various gamma rays energies by simulation and experimental methods
High Purity Germanium detectors (HPGe) are subdivisions of semiconductor detectors which are widely used in nuclear technology from space industry to nuclear medicine, due to their high resolution, low dead time, unlimited size and compatibility with a variety of environments. The( absolute and intrinsic) efficiency of the HPGe detector, which depends on the geometry of the source-detector syst...
متن کاملComparative assessment of the accuracy of maximum likelihood and correlated signal enhancement algorithm positioning methods in gamma camera with large square photomultiplier tubes
Introduction: The gamma cameras, based on scintillation crystal followed by an array of photomultiplier tubes (PMTs), play a crucial role in nuclear medicine. The use of square PMTs provides the minimum dead zones in the camera. The camera with square PMTs also reduces the number of PMTs relative to the detection area. Introduction of a positioning algorithm to improve the spat...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Kaku igaku. The Japanese journal of nuclear medicine
دوره 39 4 شماره
صفحات -
تاریخ انتشار 2002