Slab selective, regularized RF shimming
نویسندگان
چکیده
Introduction RF shimming is a well-known technique, where amplitudes and phases of a transmit RF coil array are optimized to obtain a homogeneous B1 profile, i.e., to compensate wave propagation effects at main fields of 3T or above (see, e.g., [1]). Among other anatomies, legs are particularly prone to wave propagation effects due to their bi-cylindrical geometry, resulting in significant signal and contrast inhomogeneities. This study applies RF shimming using a whole-body, eight-channel Tx/Rx system at 3T [2,3] in an optimised way. A slab selective, separate but simultaneous excitation of two different regions was evaluated in the framework of frequency-encoded transmission (multi-frequency excitation "MULTIFEX") [4,5]. Furthermore, regularized RF shimming [6] was applied to avoid inhomogeneity compensation on the cost of high SAR. Theory It is known from single channel excitation that multi-frequency RF pulses facilitate simultaneous multi-slab excitation [4]. For RF shimming, this concept offers the possibility to apply different B1 shim settings (amplitude and phase) to different parts of the body [5]. However, multifrequency RF pulses suffer from increased SAR. A multi-transmit system might balance this disadvantage by driving different Tx elements at single, but different frequencies. For instance, the odd-numbered elements can be driven at frequency f1 encoding slab 1, the even numbered elements at frequency f2 encoding slab 2 [5]. In this case, the degrees of freedom per slab are reduced, however, also the occurring SAR. Assuming that each slab is encoded by n = 1...N transmit elements, the complex channel weights An = |An| exp(iφn) are determined by minimizing the error function δ (Eq. (1), see [6]) with B1n the spatial sensitivity distribution of transmit channel n and tot B1 the spatial average of B1tot. The first term of δ minimizes the B1 inhomogeneity. The second term of δ minimizes the total forward RF power n n A to avoid inhomogeneity compensation on the cost of high RF power. The freely adjustable regularization parameter λ describes the trade-off between the two terms. This approach indirectly helps to keep SAR low, which is a cheap alternative to the typically very extensive, exact SAR calculations. The obtained SAR reduction might be used to counterbalance the SAR increase caused by the introduction of multi-frequency RF pulses. Methods A 3T MR system (Philips Achieva, Philips Medical System, Best, The Netherlands) equipped with an 8-element Tx/Rx body coil and the corresponding RF channels [2,3] was used. The transmit sensitivities B1n of the thigh bones of 4 healthy volunteers were acquired using an inverted version of “Actual Flip angle Imaging” [7,8] (TR1/TR2/TE=40/200/3.5 ms, α=70°, voxel size 8.7×8.7×10 mm). The following three RF shimming modes have been tested. (A) Simultaneously shimming of the legs with all 8 Tx elements. (B) Separate shimming of the left and right leg using the 4 left and right Tx elements. This mimics two groups of Tx elements with different single frequency pulses, which encode the two sagittal slabs corresponding to the two legs. (C) Separate shimming of the legs with all 8 Tx elements. This mimics dual frequency pulses, encoding the two sagittal slabs of the two legs. Furthermore, regularization was applied via Eq. (1) to minimize the total RF power. The obtained shim values were applied to an FDTD model [9] to confirm the inherent SAR reduction of the RF power regularization. Results Fig. 1 compares the B1 maps of the standard quadrature mode (Q) with the above-described shimming modes (A)-(C) for an example volunteer. While standard RF shimming (A) removes a large part of the B1 inhomogeneities observed in quadrature mode, frequency encoded excitation shows a significant further reduction of the inhomogeneities. The difference between (B) and (C), i.e., using single/dual frequency pulses, seems to be negligible. Thus, for this volunteer, the single frequency mode (B) is preferable for the sake of lower SAR. Fig. 2 shows the corresponding results averaged over all 4 volunteers. Fig. 3 shows the influence of the regularization for shimming mode (B) for the example volunteer. Here, allowing a small B1tot homogeneity degradation of, e.g., 2%, regularization is able to reduce the RF power by roughly a factor 3. Corresponding local SAR data from a FDTD model [9] confirm the correlation between RF power and local SAR (Fig. 3). Discussion / Conclusion At 3T, large B1 inhomogeneities are visible in leg images, which can be compensated by the presented regularized slabselective version of RF shimming. It is expected that also other applications, e.g., mammography, benefit from this localised RF shimming approach.
منابع مشابه
Enhanced Slab Selective Brain Imaging at 3T using Wide Band Tailored RF pulses
Introduction T1 weighted brain imaging at 3T for both clinical and neuroscience applications is often done using slab selective MPRAGE [1] sequences that provide flexible 3D coverage. RF field (B1) non-uniformity is an inherent problem for high field MRI and for this type of sequence results in variable image contrast. In order to compensate for this, various B1 inhomogeneity mitigating RF puls...
متن کاملGain of Imaging Fidelity by Employing a Higher Number of Independent Transmit Channels Together with Slice-Selective Radio-Frequency (RF) Shimming at 7T
Dielectric resonance effects and radio-frequency (RF) power deposition have become challenging issues for magnetic resonance imaging at ultrahigh-field (UHF) strengths. The use of transmit (Tx) coil arrays with independently-driven RF sources using a parallel transmission system is a promising method for alleviating the resulting RF inhomogeneities. In this study, the effect on homogeneity and ...
متن کاملDynamically Applied Multiple B1+ Shimming Scheme for Arterial Spin Labeling of the Prostate at 7t
Introduction: The increased longitudinal relaxation time of the blood at ultrahigh field (UHF) can improve non-contrast enhanced perfusion imaging using arterial spin labeling (ASL), especially for targeted tissues with long arterial transit times and/or intrinsic low perfusion, such as the prostate. One well-known challenge for UHF imaging is the destructive interference of RF pulses (1), whic...
متن کاملHadamard Encoded 3D MRSI of Human Brain at 7T
Introduction: At 7T in the human brain reduced RF amplitude and increased spectral dispersion result in chemical shift dispersion (CSD) artifacts that can distort metabolite ratios. For 2D encoding within the plane of a slice, CSD artifacts can be eliminated by replacing in-plane gradient based slab selective refocusing with RF shimming based outer volume suppression. However, for 3D acquisitio...
متن کاملFast low-specific absorption rate B0 -mapping along projections at high field using two-dimensional radiofrequency pulses.
PURPOSE At 7 Tesla (T), conventional static field (B0 ) projection mapping techniques, e.g., FASTMAP, FASTESTMAP, lead to elevated specific absorption rates (SAR), requiring longer total acquisition times (TA). In this work, the series of adiabatic pulses needed for slab selection in FASTMAP is replaced by a single two-dimensional radiofrequency (2D-RF) pulse to minimize TA while ensuring equal...
متن کامل