Gain of Imaging Fidelity by Employing a Higher Number of Independent Transmit Channels Together with Slice-Selective Radio-Frequency (RF) Shimming at 7T
نویسندگان
چکیده
Dielectric resonance effects and radio-frequency (RF) power deposition have become challenging issues for magnetic resonance imaging at ultrahigh-field (UHF) strengths. The use of transmit (Tx) coil arrays with independently-driven RF sources using a parallel transmission system is a promising method for alleviating the resulting RF inhomogeneities. In this study, the effect on homogeneity and RF-power when employing a higher number of transmit channels with multi-slice acquisition in vivo at high field strength (7T) is scrutinized. An 8-channel head coil array was driven to emulate circular polarized (CP) and 2-, 4-, and 8-channel independent transmit configurations at 7T. Static RF shimming was employed on human subjects in order to homogenize the B₁⁺ field in the excited volume. Slice-selective and global RF shimming methods were applied with CP and 2-, 4-, and 8-channel transmit channel configurations. RF shimming was performed from CP to 2-, 4-, and 8-channel Tx configurations globally and slice-selectively. Systematic improvement in B₁⁺ homogeneity and/or reduction in RF-power were observed. RF shimming in the human brain with 8-channel transmit and slice-selective shimming yields an increase in B₁⁺ homogeneity of 43% and/or reduces RF-power by 68% when compared with CP global RF shimming at 7T.
منابع مشابه
A 32-Channel Parallel Exciter/Amplifier Transmit System for 7T Imaging
Introduction: Parallel transmission (Tx) generalizes conventional Tx and RF shimming, offering extra degrees of freedom and significant opportunities for optimizing Tx performance, improving pulse design trade-off, and leveraging new coil concepts. The present work of developing a 32 Tx-channel system reflects an interest in 1) exploring the opportunities thoroughly and acquiring insights to th...
متن کاملCombination of Basic and Tailored RF Shimming using Curved Spoke Trajectories
Introduction In principle, two different approaches are reported to diminish wave propagation effects, and thus, improve B1 homogeneity with parallel transmission. The first approach is given by "basic" RF shimming, adjusting amplitude and phase of the different transmit channels to obtain a homogeneous B1 distribution [1]. The second approach is given by "tailored" RF shimming, i.e., multidime...
متن کاملTransmit Arrays and Circuitry
For body dimensions at 3T and head dimensions at 7T and above the RF wavelength in dielectric tissue is comparable or smaller than the dimensions of the human anatomy. This in turn leads to RF phase related traveling time differences, prominent wave behavior and the potential for a significant difference between transmit B1 + and receive B1 fields [5-10]. It is possible to correct some of the r...
متن کاملLeft Coronary Artery Imaging at 7T: Initial Results using Multiple B1+ Shimming Algorithms and Targets
INTRODUCTION: Performing right coronary artery imaging at 7T has been shown to improve the signal to noise (SNR) and contrast to noise (CNR) compared to 3T when using a turbo-FLASH (TFL) acquisition with an adiabatic spectrally selective RF pre-pulse (SPAIR) for lipid suppression (1). However, to date, imaging of the left coronary artery (LCA) has not been shown, with the suggested challenge be...
متن کاملHigh-Speed RF Modulation System for 32 Parallel Transmission Channels at 7T
Introduction: Higher field strengths in MRI are well known for their potential to increase image resolution due to higher signal-to-noise ratio (SNR). However, due to the high dielectric permittivity of human tissue and higher resonance frequencies, and thus shorter wavelengths on the order of the human body size, RF interference artifacts are likely to occur. To overcome these constraints, par...