Comparative study between a commercial and a homemade capillary electrophoresis instrument for the simultaneous determination of aminated compounds by induced fluorescence detection.

نویسندگان

  • Silvia Casado-Terrones
  • Sonia Cortacero-Ramírez
  • Alegría Carrasco-Pancorbo
  • Antonio Segura-Carretero
  • Alberto Fernández-Gutiérrez
چکیده

The performance of two capillary electrophoresis (CE) instruments, one commercial and one homemade device, were compared for the determination of derivatised aminated compounds with fluorescein isothiocyanate (FITC). The commercial CE system first uses an argon ion laser as excitation source; the homemade CE device uses an inexpensive blue-light-emitting diode (LED) as the light source and a charge-coupled device (CCD) as the detection system. After fine optimisation of several separation parameters in both devices, a co-electroosmotic flow CE methodology was achieved in coated capillary tubing with 0.001% hexadimetrine bromide (HDB), and 50 mmol L-1 sodium borate at pH 9.3 with 20% 2-propanol for the determination of several amines and aminoacids. Analytical performances, applicability in beer samples and other aspects such as cost or potential for miniaturization have been compared for both devices.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Potential determination of aminated pesticides and metabolites by cyclodextrin capillary electrophoresis-laser-induced fluorescence using FITC as labelling.

We describe a detailed study on the possibility of analyzing aminated pesticides and metabolites using pre-column derivatization with fluorescein isothiocyanate (FITC) and their subsequent separation and detection by cyclodextrin capillary electrophoresis-laser-induced fluorescence (CE-LIF) detection. Different variables affecting the derivatization reaction (pH, FITC concentration, reaction ti...

متن کامل

Determination of Aciclovir and its Related Substance Guanine in Bulk Drug and Tablet Preparation by Capillary Electrophoresis

Two Capillary Zone electrophoresis (CZE) methods were developed in this study, one using an acidic buffer (sodium citrate pH = 2.5) and the other using a basic buffer (sodium tetraborate pH = 9.8). The two methods were compared on the basis of repeatability and reproducibility of results and the CZE method developed with the basic buffer was then selected for further studies. The method was ful...

متن کامل

Determination of Aciclovir and its Related Substance Guanine in Bulk Drug and Tablet Preparation by Capillary Electrophoresis

Two Capillary Zone electrophoresis (CZE) methods were developed in this study, one using an acidic buffer (sodium citrate pH = 2.5) and the other using a basic buffer (sodium tetraborate pH = 9.8). The two methods were compared on the basis of repeatability and reproducibility of results and the CZE method developed with the basic buffer was then selected for further studies. The method was ful...

متن کامل

Capillary electrophoresis with LED-induced native fluorescence detection for determination of isoquinoline alkaloids and their cytotoxicity in extracts of Chelidonium majus L.

In this study, we introduced a simple and sensitive method of capillary electrophoresis with ultraviolet light-emitting diode-induced native fluorescence (UV-LEDIF) detection for the determination of isoquinoline alkaloids in extracts of Chelidonium majus L. Samples were extracted with acidic methanol and the extracts were directly analysed by CE. Simultaneous determination of protopine, chelid...

متن کامل

A simple light-emitted diode-induced fluorescence detector using optical fibers and a charged coupled device for direct and indirect capillary electrophoresis methods.

We constructed a simple fluorescence detector for both direct and indirect CE methods using a blue light-emitted diode (470 nm) as excitation source, a bifurcated optical fiber as a waveguide, and a CCD camera as a detector. The connection of all the components is fairly easy even for nonexperts and the use of a CCD camera improves the applicability of this detector compared to the others using...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical and bioanalytical chemistry

دوره 386 6  شماره 

صفحات  -

تاریخ انتشار 2006