Measurement of ferric ion diffusion coefficient in Fricke-infused agarose gel from MR image intensity changes

نویسندگان

  • Yin-Jiun Tseng
  • Woei-Chyn Chu
  • Sung-Cheng Huang
چکیده

Abstract-A mathematical modeling was adopted to calculate the ferric ion diffusion coefficient based on the radiation induced magnetic resonance (MR) image intensity change in Fricke-agarose gels. A fast magnetic resonance imaging acquisition technique was employed to avoid the smearing of acquired data due to diffusion over an extended period of time. Our results showed that for a Fricke-agarose gel contained 1mM ammonium ferrous sulfate, 1% agarose, 1mM sodium chloride and 50mM sulfuric acid, its ferric ion diffusion coefficient is 1.31×10-2cm2h-1 in room temperature. This value falls within the 1 ~ 2×10-2cm2h-1 range obtained by previous studies under varying concentrations of gel ingredients. KeywordsMRIFricke-infused gel dosimetry, ferric ion diffusion, gamma knife radiosurgery

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Diffusion measurement in ferrous infused gel dosimeters

Background: The compositions of Ferrous sulphate, Agarose and Xylenol orange dye (FAX) and Ferrous sulphate, Gelatin and Xylenol orange dye (FGX) in solution of distilled water and sulphuric acid are two tissue-equivalent gel dosimeters. Ionizing radiation causes oxidation of Fe2+ ion to Fe3+ ions which diffuse through the gel matrix and blur the image of absorbed dose over a period of hours af...

متن کامل

3D MRI gel dosimetry based on image intensity (A new approach)

Background: Since 1984 MRI gel dosimetry has been introduced as a potential technique for 3D dosimetry. Most of the studies have measured R1 (1/T1) or R2 (1/T2) properties of the gel depending on the gel type. We have studied image intensity change in the Fricke gel by different MRI protocols. Materials and Methods: Gel Dosimeters contain 0.4 mM ferrous sulphate, 1 mM NaCl, 50 mM H2SO4 and 1% b...

متن کامل

Diffusion measurement in ferrous infused gel dosimeters

Background: The compositions of Ferrous sulphate, Agarose and Xylenol orange dye (FAX) and Ferrous sulphate, Gelatin and Xylenol orange dye (FGX) in solution of distilled water and sulphuric acid are two tissue-equivalent gel dosimeters. Ionizing radiation causes oxidation of Fe ion to Fe ions which diffuse through the gel matrix and blur the image of absorbed dose over a period of hours after ...

متن کامل

Fricke Gel Dose Indicators Applicable for Blood Irradiators

Introduction: Transfusion of irradiated blood is recommended by the guidelines for cardiosurgery, cancer surgery, severe trauma and congenital immune deficient recipients. To prevent post- transfusion graft-versus-host disease (PT-GVHD), blood cells may be irradiated by gamma rays. The absorbed dose range for blood irradiation is typically 15 to 50 Gy. As the assurance that blo...

متن کامل

Visibility of calcium on MR and CT: can MR show calcium that CT cannot?

PURPOSE To test the hypothesis that calcium can be visible on MR images without being visible on CT. METHODS Five different calcium salts ranging in concentration from 0 to 0.45 g/mL were suspended in 2% agarose gel and studied using T2-weighted MR, T1-weighted MR, and CT. MR signal intensity, CT attenuation, and image noise were measured. Relative visibility was determined from these measure...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2001