Concepts of Nanoparticle Dose Metric and Response Metric

نویسندگان

  • Günter Oberdörster
  • Eva Oberdörster
  • Jan Oberdörster
چکیده

Wittmaack (2007) did not agree with our suggestion (Oberdörster et al. 2005) that particle surface area is a more appropriate dose metric than particle mass or particle number when evaluating dose–response relationships of nanoparticle-induced pulmonary inflammation. According to his understanding of nanotoxicology and based on his calculations, he found particle number to work best as a dose metric. Throughout our review we pointed out that the surface area concept should be considered in the context of nanoparticle surface properties such as chemistry, charge, coating , crystallinity, porosity, and reactivity. For example, nano-titanium dioxide (TiO 2) or nano-copper particles, very distinct from one another, will predictively create separate well-fitting surface area dose–response relationships. Yes, particle number is of importance as well, as we indicated in our review, but not as a direct dose metric. We would like to address some of the issues Wittmaack (2007) raised in his article. First, Wittmaack suggested that when expressing a pulmonary inflammatory response, a response metric is better done using the ratio of lavaged neutrophils (PMN; polymorphonuclear leukocytes) to macrophages instead of using the fraction of PMNs. Because the purpose of our review (Oberdörster et al. 2005) was not to describe these responses in mathematical terms (whether threshold, linear, or nonlinear) but rather to illustrate that dose–response relationships on a mass basis—but not on a surface area basis—are very different, the choice of the response metric is irrelevant. To demonstrate this, we present our data again (Figure 1), expressed as absolute numbers of elicited PMNs and as PMN/macrophage ratios as a function of administered mass (Figure 1A,B), number (Figure 1C,D), or surface area (Figure 1E,F) of fine and ultrafine (nanosized) TiO 2. The dose–response relationships based on mass and surface area are essentially the same as those shown in our review (Oberdörster et al. 2005) using the percentage of elicited neutrophils. Second, regarding the issue of particle number being the best dose metric, the particle number dose–response relationships (Figure 1B) are several orders of magnitude apart for fine and ultrafine TiO 2 , whereas the surface area plot (Figure 1C) shows a good fit for the combined particle sizes. The reviewers of Wittmaack's article (2007) apparently overlooked this flaw in his argument. Finally, Wittmaack (2007) calculated that the surface area for ultrafine TiO 2 should be 77 m 2 /g and not 50 m 2 /g, as we reported (Oberdörster et al. 2005). He derived …

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

On the Structure of Metric-like Spaces

The main purpose of this paper is to introduce several concepts of the metric-like spaces. For instance, we define concepts such as equal-like points, cluster points and completely separate points. Furthermore, this paper is an attempt to present compatibility definitions for the distance between a point and a subset of a metric-like space and also for the distance between two subsets of a metr...

متن کامل

SOME COUPLED FIXED POINT RESULTS ON MODIFIED INTUITIONISTIC FUZZY METRIC SPACES AND APPLICATION TO INTEGRAL TYPE CONTRACTION

In this paper, we introduce fruitful concepts of common limit range and joint common limit range for coupled mappings on modified intuitionistic fuzzy metric spaces. An illustrations are also given to justify the notion of common limit range and joint common limit range property for coupled maps. The purpose of this paper is to prove fixed point results for coupled mappings on modified intuitio...

متن کامل

A weighted metric method to optimize multi-response robust problems

In a robust parameter design (RPD) problem, the experimenter is interested to determine the values of con-trol factors such that responses will be robust or insensitive to variability of the noise factors. Response sur-face methodology (RSM) is one of the effective methods that can be employed for this purpose. Since quality of products or processes is usually evaluated through several quality ...

متن کامل

Common Fixed Point Theory in Modified Intuitionistic Probabilistic Metric Spaces with Common Property (E.A.)

In this paper, we define the concepts of modified intuitionistic probabilistic metric spaces, the property (E.A.) and  the common property (E.A.) in   modified  intuitionistic probabilistic metric spaces.Then, by the commonproperty (E.A.), we prove some common fixed point theorems in modified intuitionistic Menger probabilistic metric spaces satisfying an implicit relation.

متن کامل

LINEAR HYPOTHESIS TESTING USING DLR METRIC

Several practical problems of hypotheses testing can be under a general linear model analysis of variance which would be examined. In analysis of variance, when the response random variable Y , has linear relationship with several random variables X, another important model as analysis of covariance can be used. In this paper, assuming that Y is fuzzy and using DLR metric, a method for testing ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 115  شماره 

صفحات  -

تاریخ انتشار 2007