Predicting the optical performance of eyes implanted with IOLs to correct spherical aberration.
نویسندگان
چکیده
PURPOSE To use powerful modeling techniques for predicting the optical performance of eyes implanted with different types of intraocular lenses (IOLs). This approach will allow performance of "virtual cataract surgery," with different IOL designs that can be used and physical parameters that may occur during actual surgery-in particular, in IOLs that correct spherical aberration. METHODS A computer model was developed to predict the optical performance of individual eyes after IOL implantation. The approach was validated in a group of patients with eyes implanted with different IOLs. In these patients, corneal wavefront aberrations were calculated from elevations provided by videokeratography. Ocular aberrations were measured with a high-dynamic range Hartmann-Shack wavefront sensor. Misalignments (IOL tilt and decentration) were estimated with a new instrument, based on recording Purkinje images. This model of particular corneal aberrations and IOL parameters (intrinsic optical design details plus geometric location data) was used to estimate the total ocular aberrations after surgery and to compared them with actual aberrations measured directly with the wavefront sensor. RESULTS The aberrations of implanted eyes predicted by the individualized optical models were well correlated with the actual aberration measured in each subject. This result indicates that the approach is adequate in evaluating the actual optical performance of different types of lenses. The model allows a large number of "virtual" surgeries to be performed, to test the performance of current or future IOL designs. CONCLUSIONS A "virtual surgery" approach was designed to predict the optical performance in pseudophakic eyes. In each subject, it was possible to obtain the eye's optical performance with a particular IOL and biometric data after surgery. Specifically, this modeling can be used to evaluate the tolerances to misalignments and depth of focus of IOLs correcting spherical aberration in actual eyes. This approach is quite powerful and is especially applicable to the study of current and future aberration-correction IOL designs.
منابع مشابه
Optical quality and depth-of-field of eyes implanted with spherical and aspheric intraocular lenses.
PURPOSE To compare experimental optical performance in eyes implanted with spherical and aspheric intraocular lenses (IOLs). METHODS Corneal, total, and internal aberrations were measured in 19 eyes implanted with spherical (n=9) and aspheric (n=10) IOLs. Corneal aberrations were estimated by virtual ray tracing on corneal elevation maps, and total aberrations were measured using a second-gen...
متن کاملCorneal spherical aberration and its impact on choosing an intraocular lens for cataract surgery.
PURPOSE To analyze the post operative results of targeting zero spherical aberration by selecting the best-fit aspheric intraocular lens (IOL), based on preoperative corneal spherical aberration of patients with phacoemulsification surgery. SETTING AlHokama Eye Specialist Center, Riyadh, Saudi Arabia. PERIOD From the 1st of October 2012 until the 10th of April 2013. METHODS Fifty-three ey...
متن کاملComparison of Higher-Order Aberration and Contrast Sensitivity in Monofocal and Multifocal Intraocular Lenses
PURPOSE The visual performance of pseudophakic eyes depends on the type of intraocular lenses (IOLs) that are implanted. Aspherical and multifocal IOLs have recently been developed to improve visual quality after cataract surgery, but multifocal IOLs can be associated with decreased contrast sensitivity (CS), halos, and glare. This study compares the visual performance of monofocal and multifoc...
متن کاملDifferences of Longitudinal Chromatic Aberration (LCA) between Eyes with Intraocular Lenses from Different Manufacturers
Several researchers have studied the longitudinal chromatic aberration (LCA) of eyes implanted with an intraocular lens (IOL). We investigated the LCA of eyes implanted with yellow-colored IOLs from three different manufacturers: Alcon Inc., HOYA Corp., and AMO Inc. The number of subjects was 11, 16, and 16, respectively. The LCA of eyes implanted with SN60WF and SN60AT (Alcon Inc.), and with X...
متن کاملIn vitro strehl ratios with spherical, aberration-free, average, and customized spherical aberration-correcting intraocular lenses.
PURPOSE To determine in vitro image qualities of artificial eyes achieved with spherical, aberration-free, average spherical aberration-correcting, and customized spherical aberration-correcting IOLs in centered, decentered, and tilted positions. METHODS The in vitro performance of these IOL models was determined by optical bench measurements. The experimental setup included a laser light sou...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 47 10 شماره
صفحات -
تاریخ انتشار 2006