An in vitro comparison of hand and rotary instruments in preparing root canal system

نویسنده

  • Azza A Dafalla
چکیده

Introduction: The aim of the present study was to compare hand stainless steel K-files and Nickel-titanium Profile 0.04 taper 29 series rotary instruments for their efficiency, procedural errors and time consumed in preparation of root canal system. Materials and Methods: A total of 46 maxillary and mandibular first premolars extracted for orthodontic purposes were collected (two contralateral teeth from each individual). The samples were divided into two groups of 34 canals each. Teeth in the first group were prepared with stainless steel hand K-files while the second groups were prepared with profile 0.04 taper series 29 rotary files. Preparation period was recorded for both groups. Impression material was introduced to the prepared canals so that the replica of prepared canals was achieved. These were assessed under stereomicroscope to assess the efficiency in preparing canals in respect to canal smoothness, ability of impression material to flow and quality of taper. Results: Results showed significantly shorter preparation time for Profile than K-file. 8.8% of the canals prepared with K-files showed canal blockage, while all canals prepared with Profile remained patent. Alterations in working length working distance appeared in 23.5% of canals prepared with K-file and 11.7% in canals prepared with Profile. Failed instruments in K-files were significantly higher, mostly deformation (P<0.001). Profiles failed instruments were in the form of fracture and no deformation was detected. Both systems showed unsatisfactory walls smoothness and flow. Conclusion: Within the limitation of this in vitro study it was concluded that Profile 0.04 taper series 29 rotary systems prepare canals more rapidly, and showed lower incidences of fracture and blockages, and only limited loss of working length. Canal preparation with K-file was time consuming and showed higher incidence of deformed instruments that was probably due to low elasticity of the stainless steel metal that caused the file to permanently deform within the canal. Both systems showed unsatisfactory results for canal walls smoothness and flow, however, K-files showed better quality of canal taper. [Iranian Endodontic Journal 2010;5(4):167-73]

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of remaining obturating material on canal walls using rotary and hand instrumentation techniques for endodontic re-treatment

Comparison of remaining obturating material on canal walls using rotary and hand instrumentation techniques for endodontic re-treatment Dr. J. Ghoddusi*- Dr. P. Ghaziani*- Dr. Sh. Nazari** *Associate Professor of Endodontics Dept., Faculty of Dentistry, Mashhad University of Medical Sciences. **Assistant Professor of Endodontics Dept., Faculty of Dentistry, Hamedan University of Medical Science...

متن کامل

A comparison of transportation and time of canal preparation with stainless steel hand instruments and Ni-Ti rotary systems (In – Vitro)

A comparison of transportation and time of canal preparation with stainless steel hand instruments and Ni-Ti rotary systems (In – Vitro) Dr. MR. Sharifian* - Dr. MH. Nekoofar* - Dr. P. Motahari** - Dr. A. Tavakoli*** *-Assistant Professor of Endodontics Dept. – Faculty of Dentistry – Tehran University of Medical Sciences. **- Assistant Professor of Oral and Maxillofacial Pathology Dept. – Facul...

متن کامل

Shaping Ability of NiTi Rotary versus Stainless-Steel Hand Instruments in Curved Root Canals of Extracted Teeth

Introduction: The purpose of this in-vitro study was to compare shaping ability of NiTi rotary Mtwo and FlexMaster with stainless steel hand K-Flexofile in curved root canals of extracted teeth. Materials and Methods: Mesiobuccal canals of 45 mandibular molar teeth were balanced into three groups of 15 each, with respect to the Schneider angle, canal access angle, height, dis-tance and radiu...

متن کامل

A comparison of apically extruded debris between conventional and 2 rotary instrumentation techniques according to the number of applications(An in vitro study)

A comparison of apically extruded debris between conventional and 2 rotary instrumentation techniques according to the number of applications(An in vitro study) Dr. MH. Zarabi* - Dr. H. Djafarzadeh** - Dr. M. Bidar** *- Associate Professor of Endodontics Dept. - Faculty of Dentistry – Mashhad University of Medical Sciences. **- Endodontist. Background and Aim: Various kinds of hand or rotary te...

متن کامل

In-vitro Comparison of NiTi Tee, RaCe and Protaper Instruments in Dentinal Crack Formation

Background and Aim:Root canal preparation with rotary instruments may cause dentinal cracks leading to tooth fracture. The aim of this study was to compare three different rotary systems ProTaper, RaCe and Niti Tee on formation of dentinal cracks following root canal preparation. Materials and Methods: In this experimental study, 50 extracted mandibular first molars were selected. Teeth having ...

متن کامل

Comparison of apically extruded debris and instrumentation time using rotary, endodontic handpiece and hand files in primary molar teeth: (In-vitro )

Abstract Background & Aim : This study was aimed to compare the instrumentation time and the amount of debris extruded apically  during root canal preparation using hand files ,Mtwo rotary system and endodontic handpiece  in primary molar teeth. Method & Material : In this experimental study, sixty roots of  primary molars of human teeth were assigned to three groups (for each group, n=20). The...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010