Effect of heparin surface modification in reducing silicone oil adherence to various intraocular lenses.

نویسندگان

  • S N Arthur
  • Q Peng
  • D J Apple
  • M Escobar-Gomez
  • R Bianchi
  • S K Pandey
  • L Werner
چکیده

PURPOSE To evaluate surface properties of various intraocular lenses (IOLs), including a newly fabricated heparin-surface-modified (HSM) silicone IOL, with special reference to their efficiency in reducing potential silicone oil adherence to the IOL optics. SETTING Center for Research on Ocular Therapeutics and Biodevices, Department of Ophthalmology, Storm Eye Institute, Medical University of South Carolina, Charleston, South Carolina, USA. METHODS Five groups of rigid and foldable IOLs were analyzed in an in vitro test for the percentage of silicone oil adherence: a single-piece foldable hydrophilic-acrylic IOL (n = 9); a single-piece rigid poly(methyl methacrylate) (PMMA) IOL with HSM coating of the lens optic (n = 9); a 3-piece foldable silicone optic IOL with HSM coating of the optic (n = 10); a single-piece standard rigid PMMA IOL (n = 7); and a standard 3-piece foldable silicone optic IOL (n = 9). After the IOLs were immersed in water and then in silicone oil, gross photographs taken. Image analysis was performed to evaluate the percentage of silicone oil coverage of the anterior and posterior surfaces of each IOL optic. RESULTS The mean silicone oil coverage of the hydrophilic-acrylic IOLs was 5.6% +/- 2.5% (SD); of the HSM PMMA IOLs, 6.2% +/- 4.3%; of the HSM silicone optic IOLs, 6.7% +/- 3.2%; and of the standard PMMA IOLs, 20.3% +/- 13.3%. The mean silicone oil coverage was greatest on the standard silicone optic IOLs, 98.2% +/- 3.1%. CONCLUSIONS Intraocular lenses with a hydrophilic optic have less tendency toward adherence to silicone oil than more hydrophobic designs. A foldable silicone IOL with heparin surface modification can significantly reduce potential silicone oil adherence, comparable to the level achievable with the rigid HSM PMMA designs. Two new foldable IOL styles, the HSM silicone IOL and IOLs in the general class of hydrophilic-acrylic, were highly efficacious in reducing silicone oil adherence. There is now a real choice of foldable lenses for patients with actual or potential vitreoretinal diseases.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

[In vitro adherence of Staphylococcus epidermidis and Pseudomonas alcaligenes to intraocular lenses].

PURPOSE To quantify and compare the in vitro adherence of Staphylococcus epidermidis and Pseudomonas alcaligenes to different intraocular lenses (IOLs). METHODS Fourteen intraocular lenses were used in the experiment. Four of polymethylmethacrylate (PMMA), four of silicone, four of hydrogel and two of acrylic. Eight intraocular lenses were placed in eight test tubes containing 4 ml of Pseudom...

متن کامل

Femtosecond laser-assisted cataract surgery in vitrectomized eye with posterior chamber phakic intraocular lens.

We describe a case of femtosecond laser-assisted cataract surgery (FLACS) in an eye with multiple comorbidities, including retinal detachment surgery, high myopia, posterior chamber phakic intraocular lens (PC pIOL) and residual, emulsified, silicone oil located in the anterior chamber. FLACS was affected by the optical blockage, but the incomplete capsular tear was recoverable. The case sugges...

متن کامل

Surface Modification of Silicone Rubber Membrane by Microwave Discharge to Improve Biocompatibility

      Wetability of biocompatible polymers can be improved by plasma surface modification. The purpose of this study was to surface modify an experimental poly (dimethylsiloxane) rubber (PDMS) material in order to improve its wetability and biocompatibility. Surface properties of the PDMS were characterized using contact angles measurement for wetability analysis. Samples of experimental silico...

متن کامل

Silicone oil removal. I. The effect on the complications of silicone oil.

The results of a retrospective study of the effects of silicone oil removal from 85 eyes in 85 patients are reported. Pars plana vitrectomy and fluid/silicone oil exchange had been undertaken for retinal detachments associated with giant retinal tears or with proliferative vitreoretinopathy in all cases. Clinically significant cataract developed in 60% of lenses that were clear at the time of o...

متن کامل

Interaction with intraocular lens materials: does heavy silicone oil act like silicone oil?

PURPOSE To determine the interaction of heavy silicone oil with various intraocular lens (IOL) materials and whether heavy silicone oil covers the silicone IOL optic as silicone oil does. SETTING Department of Ophthalmology, Dokuz Eylul University, Izmir, Turkey. METHODS The study group comprised 5 poly(methyl methacrylate) (PMMA) IOLs, 4 foldable silicone IOLs, 5 foldable hydrophilic acryl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of cataract and refractive surgery

دوره 27 10  شماره 

صفحات  -

تاریخ انتشار 2001