Determination of phenol compounds in surface water matrices by bar adsorptive microextraction-high performance liquid chromatography-diode array detection.

نویسندگان

  • Nuno R Neng
  • José M F Nogueira
چکیده

Bar adsorptive microextraction combined with liquid desorption followed by high performance liquid chromatography with diode array detection (BAµE-LD/HPLC-DAD) is proposed for the determination of trace levels of five phenol compounds (3-nitrophenol, 4-nitrophenol, bisphenol-A, 4-n-octylphenol and 4-n-nonylphenol) in surface water matrices. By using a polystyrene-divinylbenzene copolymer (PS-DVB) sorbent phase, high selectivity and efficiency is achieved even against polydimethylsiloxane through stir bar sorptive extraction. Assays performed by BAµE(PS-DVB)-LD/HPLC-DAD on 25 mL water samples spiked at the 10.0 µg/L levels yielded recoveries over 88.0%±5.7% for all five analytes, under optimized experimental conditions. The analytical performance showed good precision (RSD<15%), detection limits of 0.25 µg/L and linear dynamic ranges (1.0-25.0 μg/L) with determination coefficient higher than 0.9904. By using the standard addition method, the application of the present method to surface water matrices allowed very good performances at the trace level. The proposed methodology proved to be a suitable alternative to monitor phenol compounds in surface water matrices, showing to be easy to implement, reliable, sensitive and requiring a low sample volume.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Use of Temperature-controlled Ionic Liquid-assisted Dispersive Liquid-Liquid Microextraction Method for the Detection of Amoxicillin, Cloxacillin and Erythromycin Residues in Cow Milk using High Performance Liquid Chromatography

Background and Objectives: Different types of antibiotics are used indiscriminately in animal husbandry for the growth and treatment of livestock, which cause accumulation of antibiotic residues in livestock products such as milk. Long-term consumption of milk contaminated with antibiotic residues above the permissible limits is harmful to human health, causing antibiotic resistance problems. T...

متن کامل

Determination of Phenol and Carvacrol in Honey Samples Using Dispersive Liquid-Liquid Microextraction and Experimental Design for Optimization

A very simple, rapid and sensitive dispersive liquid-liquid microextraction (DLLME) followed by gas chromatography and flame ionization detection (GC-FID) was developed for the determination of phenol and carvacrol in honey samples. A mixture of 100 µl dichloromethane (extraction solvent) and 0.5 ml acetonitrile (disperser solvent) was rapidly injected into sample solution. Thereby a cloudy sol...

متن کامل

Screening Method for Mononitrotoluenes in Natural Waters Using Magnetic Solvent Bar Liquid-Phase Micro-extraction Followed by Gas Chromatography-Flame Ionization Detection

A simple andefficient hollow fiber-based method,viz magnetic solvent bar liquid-phasemicroextraction (MSB-LPME) combined with gas chromatography-flame ionization detection (GCFID)has been successfully developed for the trace determination of mononitrotoluenes (MNTs) innatural water samples. The analytes were extracted from sample solution to the organic solventimmobilize...

متن کامل

Determination of some B Vitamins in Sour Cherry Juice Using Dispersive Liquid-liquid Microextraction Followed by High-performance Liquid Chromatography

Dispersive liquid-liquid microextraction method (DLLME) combined with high-performance liquid chromatography-ultraviolet detection (HPLC-UV) was used to determine thiamine (B1), nicotinamide (B3) and pyridoxine (B6) in sour cherry juice. This method was rapid, simple and sensitive. Separation was accomplished using a C18 column. The optimum chromatographic conditions were found to be: mobile ph...

متن کامل

Determination of some B Vitamins in Sour Cherry Juice Using Dispersive Liquid-liquid Microextraction Followed by High-performance Liquid Chromatography

Dispersive liquid-liquid microextraction method (DLLME) combined with high-performance liquid chromatography-ultraviolet detection (HPLC-UV) was used to determine thiamine (B1), nicotinamide (B3) and pyridoxine (B6) in sour cherry juice. This method was rapid, simple and sensitive. Separation was accomplished using a C18 column. The optimum chromatographic conditions were found to be: mobile ph...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Molecules

دوره 19 7  شماره 

صفحات  -

تاریخ انتشار 2014