Comparison of commercially available three‐dimensional treatment planning algorithms for monitor unit calculations in the presence of heterogeneities
نویسندگان
چکیده
This study uses an anthropomorphic phantom and its computed tomography (CT) data set to evaluate monitor unit (MU) calculations using the CMS Focus Clarkson, the CMS Focus Multigrid Superposition Model, the CMS Focus FFT Convolution Model, and the ADAC Pinnacle Collapsed Cone Convolution Superposition Algorithms. Using heterogeneity corrections, a treatment plan and corresponding MU calculations were generated for several typical clinical situations. A diode detector, placed in an anthropomorphic phantom, was used to compare the treatment planning algorithms' predicted doses with measured data. Differences between diode measurements and the algorithms' calculations were within reasonable levels of acceptability as recommended by Van Dyk et al. [Int. J. Rad. Onc. Biol. Phys. 26, 261-273 (1993)], except for the CMS Clarkson algorithm, which predicted too few MU for delivery of the intended dose to chest wall fields.
منابع مشابه
Evaluation of treatment planning system monitor unit calculations for three intensity modulated radiotherapy delivery techniques
Background: We have validated the monitor unit calculations from a commercially available treatment planning system (TPS) for three intensity modulated radiotherapy (IMRT) planning techniques for tangential breast irradiation by using ionization chamber measurements. Materials and Methods: Treatment plans were generated for forty-two breast patients by a forward planned field in field ...
متن کاملDosimetric Evaluation of Dose calculation algorithms of Monaco Treatment Planning System in the heterogeneities area
Introduction: In radiation therapy, the accuracy of dose calculations by a treatment planning system (TPS) is important to achieve tumor control and to spare normal tissue. Treatment planning system calculations in the heterogeneous situation may present significant inaccuracies. In this study, three different dose calculation algorithms, pencil beam (PB), collapsed cone (CC), ...
متن کاملAssessment of two different dose distribution algorithms (Clarkson and Superposition) in PCRT3D treatment planning system for Esophagus Cancer by using 3DCRT technique
Introduction: The functionality and quality of any treatment planning system (TPS) strongly depends on the type of Algorithm which is used by it. Obviously, the role of dose distribution algorithms in calculation of prescribed dose inside the tumor in modern radiotherapy techniques has more important than past to achieve the best clinical outcomes, especially in tumors which ar...
متن کاملVerification of Monitor unit calculations for eclipse Treatment Planning System by in- house developed spreadsheet
Introduction: Computerized treatment planning is a rapidly evolving modality that depends on hardware and software efficiency. Despite ICRU recommendations suggesting 5% deviation in dose delivery the overall uncertainty shall be less than 3.5% as suggested by B.J. Minjnheer. J. In house spreadsheets are developed by the medical physicists to cross-verify the dose calculated by the Treatment Pl...
متن کاملPoint Dose Measurement for Verification of Treatment Planning System using an Indigenous Heterogeneous Pelvis Phantom for Clarkson, Convolution, Superposition, and Fast Superposition Algorithms
Background: Nowadays, advanced radiotherapy equipment includes algorithms to calculate dose. The verification of the calculated doses is important to achieve accurate results. Mostly homogeneous dosimetric phantoms are available commercially which do not mimic the actual patient anatomy; therefore, an indigenous heterogeneous pelvic phantom mimicking actual human pelvic region has been used to ...