Introduction to electronic calibration and methods for correcting manufacturing tolerances in industrial equipment designs - AN4704

ثبت نشده
چکیده

This tutorial discusses how the proper design of trim, adjustment, and calibration circuits can correct system tolerances, making industrial equipment safer, more accurate, and more affordable. Calibration subjects addressed include compensating for component tolerances, using final-test calibration, improving reliability through power-on self-test and continuous/periodic calibration, enabling accurate automated adjustments, replacing mechanical trims with all-electronic equivalents, and leveraging precision voltage references for digital calibration. Making industrial equipment accurate, safe, and affordable with electronic calibration We demand safety in our factories. Customers expect quality products, which require accurate manufacturing equipment. At the same time, equipment must be affordable. How can manufacturers deliver "perfect" equipment at a reasonable price? In a word, calibration. Electronic calibration enables the remote calibration and testing of field devices such as sensors, valves, and actuators. Because field devices and programmable logic controllers (PLCs) are size constrained, they benefit from the small size of electronic calibration devices. All practical components, both mechanical and electronic, have manufacturing tolerances. The more relaxed the tolerance, the more affordable the component. When components are assembled into a system, the individual tolerances sum to create a total system error tolerance. Through the proper design of trim, adjustment, and calibration circuits, it is possible to correct these system errors, thereby making equipment safe, accurate, and affordable. Calibration can reduce cost in many areas. It can be used to remove manufacturing tolerances, specify less-expensive components, reduce test time, improve reliability, increase customer satisfaction, reduce customer returns, lower warrantee costs, and speed product delivery. Digitally controlled calibration devices and potentiometers (pots) are replacing mechanical pots in many factory settings. This digital approach results in better reliability and improved employee safety. This increased dependability can reduce product liability concerns. Another advantage is reduced test time and expense by removing human error. Automatic test equipment (ATE) can perform the test functions quickly and precisely, time after time. In addition, digital devices are insensitive to dust, dirt, and moisture, which can cause failure in mechanical pots. Testing and calibration fall into three broad areas: production-line final testing, periodic self-testing, and continuous monitoring and readjustment. Practical products may use some or all of the above test methods. Compensating for component tolerances using final-test calibration Final-test calibration corrects for errors caused by the combined tolerances of many components. One or more adjustments may be required to calibrate the device under test (DUT) to meet a manufacturer's specifications. To provide a simple example, we will say that this equipment uses resistors with five percent tolerance in several circuits. In design, we simulate the circuits and perform Monte Carlo testing. That is, we randomly change the resistor values within the tolerance limits to explore their effects on the output signal. The simulation results in a family of curves that show the worst-case errors that the resistor tolerances cause. With this knowledge, the designer decides to use the circuits as-is and to simply adjust the offset and span (gain) during final test to meet system specifications. So, we make measurements in the final production test and have a human set the span and offset using two mechanical pots. Calibration is complete, but have we solved the problem, masked the problem, or added a bigger unknown? Experienced production engineers know human error is a real issue. Unintentional slips can ruin the best of plans. Asking a human to perform a boring, repetitive task is asking for problems. A better way is to automate such a task. Electrically adjustable calibration devices enable quick automatic testing, which improves repeatability, reduces cost, and enhances safety by removing the human-error factor. Improving reliability and long-term stability by power-on self-test and continuous/periodic calibration Manufacturing tolerances are compensated for by calibration during the final production test, and that data is utilized when a system is powered up. Environmental parameters in the field also create a need for test and calibration. Such environmental factors include

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Introduction to electronic calibration and methods for correcting manufacturing tolerances in medical equipment designs - AN4703

This tutorial discusses how the proper design of trim, adjustment, and calibration circuits can correct system tolerances, making medical equipment safer, more accurate, and more affordable. Calibration subjects addressed include compensating for component tolerances, using final-test calibration, improving reliability through power-on self-test and continuous/periodic calibration, enabling acc...

متن کامل

Applications of dimensional micro metrology to the product and process quality control in manufacturing of precision polymer micro components

Precision manufacturing of micro injection moulded (mIM) components presents challenges in terms of quality control due to the miniaturization of product dimensions and tolerances. This paper addresses product compliance with specifications, focusing on tolerances of dimensions and position on mIM components selected from industrial production. Two systems were analysed: a tactile coordinate me...

متن کامل

Kinematic Coupling Interchangeability for Modular Factory Equipment

The deterministic nature of kinematic couplings enables closed-form characterization of interchangeability error, parametrized in terms of the magnitudes of manufacturing tolerances in the interface manufacturing and assembly processes. A Monte Carlo analysis is developed and validated for predicting interchangeability of canoe ball couplings, and repeatability measurements and interchangeabili...

متن کامل

Relationship between Sound Pressure Levels and the Risk of Hearing Loss using Personal Protective Equipment in Manufacturing Industries

Introduction: The sound pressure levels caused by work environment noise, along with the effects and ways of reducing it, are one of the most important issues in the manufacturing industry. Noise is the most common pollutant in the industrial environment, which can cause many disorders in various organs of the body, such as the auditory and vascular systems. This study aimed to investigate the ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010