Chemical dosing for sulfide control in Australia: An industry survey.
نویسندگان
چکیده
Controlling sulfide (H(2)S) production and emission in sewer systems is critical due to the corrosion and malodour problems that sulfide causes. Chemical dosing is one of the most commonly used measures to mitigate these problems. Many chemicals have been reported to be effective for sulfide control, but the extent of success varies between chemicals and is also dependent on how they are applied. This industry survey aims to summarise the current practice in Australia with the view to assist the water industry to further improve their practices and to identify new research questions. Results showed that dosing is mainly undertaken in pressure mains. Magnesium hydroxide, sodium hydroxide and nitrate are the most commonly used chemicals for sewers with low flows. In comparison, iron salts are preferentially used for sulfide control in large systems. The use of oxygen injection has declined dramatically in the past few years. Chemical dosing is mainly conducted at wet wells and pumping stations, except for oxygen, which is injected into the pipe. The dosing rates are normally linked to the control mechanisms of the chemicals and the dosing locations, with constant or profiled dosing rates usually applied. Finally, key opportunities for improvement are the use of mathematical models for the selection of chemicals and dosing locations, on-line dynamic control of the dosing rates and the development of more cost-effective chemicals for sulfide control.
منابع مشابه
Controlling chemical dosing for sulfide mitigation in sewer networks using a hybrid automata control strategy.
Chemicals such as magnesium hydroxide (Mg(OH)2) and iron salts are widely used to control sulfide-induced corrosion in sewer networks composed of interconnected sewer pipe lines and pumping stations. Chemical dosing control is usually non-automatic and based on experience, thus often resulting in sewage reaching the discharge point receiving inadequate or even no chemical dosing. Moreover, inte...
متن کاملOn-line Control of Magnesium Hydroxide Dosing for Sulfide Mitigation in Sewers
Magnesium hydroxide (Mg(OH)2) is commonly dosed in sewer systems to control corrosion and odour problems by preventing sulfide transfer from the liquid to the gas phase. Current dosing practices do not take the dynamics of sewage flow and sulfide production into consideration. This paper presents the development of an on-line control methodology for the optimised dosing of Mg(OH)2, based on pH ...
متن کاملOptimization of Synthesis of Expandable Polystyrene by Multi-Stage Initiator Dosing
Suspension polymerization process is commonly used to produce expandable polystyrene. In the conventional method for producing this polymer, two different initiators are added to the process at two different temperature levels. In the industrial scale, this process is time consuming and difficult to control. A new method (Multi-Stage Initiator Dosing, MID) is proposed, in which, the initiator i...
متن کاملIntegrated modelling of biotransformation processes in sewer systems and wastewater treatment plants for optimising chemical dosing to sewer networks
Hydrogen sulfide, which is produced by sewer biofilms as a result of sulfate reduction under anaerobic conditions, has since long been identified as a major cause of corrosion and odour problems in a sewer system. Dosing of various types of chemicals to wastewater is widely used by the water industry as a control measure for these problems. Oxygen/air, nitrate salts, iron salts and magnesium hy...
متن کاملSolutions to a combined problem of excessive hydrogen sulfide in biogas and struvite scaling.
The Woodman Point Wastewater Treatment Plant (WWTP) in Western Australia has experienced two separate problems causing avoidable maintenance costs: the build-up of massive struvite (MgNH4PO4. 6H2O) scaling downstream of the anaerobic digester and the formation of hydrogen sulfide (H2S) levels in the digester gas to levels that compromised gas engine operation and caused high operating costs on ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Water research
دوره 45 19 شماره
صفحات -
تاریخ انتشار 2011