Simulation of Blood Flow in Human Aorta including Thirteen Main Arteries (eccomas Cfd 2010)

نویسندگان

  • Erke Aribas
  • Senol Piskin
  • M.Serdar Celebi
  • E. Aribas
  • S. Piskin
چکیده

This paper investigates the mechanical properties of blood flow in main arterial system of human. The system includes aorta, subclavian, mesosentric, iliac artery, renal artery, celiac artery. The geometric domain of artery network is obtained using a real patient data. As an input, Womersley velocity profile [2] is used. Combination of thirteen arteries with aorta gives better understanding of the interactions of blood flow among the arteries. For example, the effect of a narrowing region at the iliac artery to the flow at aorta or renal artery can be studied with the help of the model presented. Results of the study include velocity, pressure and WSS (Wall Shear Stress) distributions at the arteries and the bifurcation regions of the arterial tree [1, 3]. Later, regional domains are inter-examined and dynamics of the system is compared within the thirteen branched model results. E. Aribas, S. Piskin and M.S. Celebi

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Study of Pulsatile Non-Newtonian Blood Flow Through Abdominal Aorta and Renal Arteries Incorporating Fluid- Structure Interaction

Background: The interaction between the blood and the vessel wall is of great clinical interest in studying cardiovascular diseases, the major causes of death in developed countries.Objective: To understand the effects of incorporating fluid-structure interaction into the simulation of blood flow through an anatomically realistic model of abdominal aorta and renal arteries reconstructed from CT...

متن کامل

Numerical Investigation of Angulation Effects in Stenosed Renal Arteries

Background: Numerical study of angulation effects of renal arteries on blood flow has been of great interest for many researchers.Objective: This paper aims at numerically determining the angulation effects of stenosed renal arteries on blood flow velocity and renal mass flow.Method: An anatomically realistic model of abdominal aorta and renal arteries is reconstructed from CT-scan images and u...

متن کامل

Blood Flow Simulation in an Aorta with a mild coarctation Using Magnetic Resonance Angiography and Finite Volume Method

Coarctation of the aorta is one of the five main congenital cardiovascular failures, accounting for 6–8 percent of these failures. This research aimed to simulate the blood flow of a seventeen-year-old male teen with a mild coarctation at one-third of his aorta's descending branch. The simulation was performed by extracting the domain and the input pulsatile velocity signal as the boundary cond...

متن کامل

Feasibility of Patient Specific Aortic Blood Flow CFD Simulation

Patient specific modelling of the blood flow through the human aorta is performed using computational fluid dynamics (CFD) and magnetic resonance imaging (MRI). Velocity patterns are compared between computer simulations and measurements. The workflow includes several steps: MRI measurement to obtain both geometry and velocity, an automatic levelset segmentation followed by meshing of the geome...

متن کامل

Acquired Infrarenal Abdominal Aortic Coarctation: Treatment with Percutaneous Self Expandable Stent

Abdominal aortic coarctation is an extremely rare vascular pathology. Its etiology can be congenital or acquired. Here we present a case of acquired infrarenal abdominal coarctation in a 66-year-old woman who complained of low back and legs pain. She had no signs of resting lower limb ischemia, with diminished distal pulses and normal blood pressure in upper and lower extremities. Magnetic reso...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010