Introduction. In the International Code of Practice for dosimetry TRS-398 published by International Atomic Energy Agency (IAEA), water is recommended as the reference medium for the determination of absorbed dose for high-energy electron beams. Plastic phantoms may be used under certain circumstances for electron beam dosimetry for beam qualities R50 < 4g/cm2 (E0 below 10 MeV). In our study, water equivalency of Plastic WaterTM was evaluated in order to determine fluence scaling factors hpl for Plastic Water. Extended set of measurements in water and in Plastic Water were performed. Material and methods. The absorbed dose was determined according to IAEA TRS-398 dosimetry protocol following recommendations for all relevant parameters involved. Water equivalency of Plastic Water was evaluated for five electron beams with nominal energies from 6 MeV to 18 MeV generated by linear accelerator Varian Clinac 2100 C/D. Adequate dosimetry equipment was used throughout the measurements and reference conditions, set by IAEA TRS-398, were followed carefully. Results. The results are presented as ratios Dpl /Dw of absorbed dose in Plastic Water and water. Upon the selection of electron energy, the ratios vary from 0.9990 1.0058 with combined uncertainties (1SD) of 0.46% 0.68%. From the measured data, the fluence scaling factors hpl were determined and found to be in the range from 0.9942 to 1.0010. Measurements were taken over a period of 18 months, within the frame of a Coordinated Research Project of the International Atomic Energy Agency. Conclusions. Our results are compatible with previously published data.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Air Kerma Based Dosimetry versus Absorbed Dose to Water Based Dosimetry for High-energy Photon

Introduction: In the last 5 years the American Association of Physicists in Medicine Task Group 51 (AAPM TG-51) and the International Atomic Energy Agency (IAEA) published a new high-energy photon and electron dosimetry protocol. These protocols are based on the use of an ion chamber having an absorbed-dose to water calibration factor. These are different from the previous NCS report-2 and IAEA...

متن کامل

Uncertainties on measurements of absorbed-dose-to-water, from clinical high- energy eletron beams: a comparison with the IAEA protocols

A pilot study was performed to verify the troubles involved in the implementation of dosimetric protocol TRS 398 for absorbed-dose-to-water, using clinical high-energy electron beams and to accomplish an detailed evaluation of uncertainty chain components associated to the measurement, which ones were not treated in the IAEA protocols, aimed the standardization of technical procedures.

متن کامل

A Comparison of dosimetric parameters between IAEA TRS-398, AAPM TG-51 protocols and Monte-Carlo simulation

Background: Two protocols of AAPM TG-51 and IAEA TRS-398 were compared followed by a measurement and Monte Carlo simulation of beam quality correction factor, KQ, AAPM TG-51 and IAEA TRS-398 protocols were compared for the absorbed dose to water for DW, and KQ parameters. Materials and Methods: Dose measurements by either protocols were performed with cylindrical and plane parallel ch...

متن کامل

Monte Carlo Calculation of Stopping-power Ratios for Clinical Electron Beams Produced by a Linac for Iort

Stopping power ratios sw,air for electron beams produced by the NOVAC7® IORT accelerator were calculated at different depths in water by the SPRRZnrc Monte Carlo code. As input for the SPRRZnrc code a phase-space data file obtained for any beam by the BEAMnrc code was used. The calculated stopping power ratios were compared with those recommended by the IAEA dosimetry protocols TRS-381 and TRS-...

متن کامل

Reference Dosimetry according to the New German Protocol DIN 6800-2 and Comparison with IAEA TRS 398 and AAPM TG 51*

The preceding DIN 6800-2 (1997) protocol has been revised by a German task group and its latest version was published in March 2008 as the national standard dosimetry protocol DIN 6800-2 (2008 March). Since then, in Germany the determination of absorbed dose to water for high-energy photon and electron beams has to be performed according to this new German dosimetry protocol. The IAEA Code of P...