Organ point dose measurements in clinical multi slice computed tomography (MSCT) examinations with the MOSkinTM radiation dosimeter

نویسندگان

  • C P. L Lian
  • D Cutajar
  • Anatoly B. Rosenfeld
  • C.P.L. Lian
  • A. Young
  • D. Cutajar
  • N. Freeman
  • A. B. Rosenfeld
چکیده

This study reports on the application of the MOSkinTM dosimeter in MSCT imaging for the real-time measurement of absorbed organ point doses in a tissue-equivalent female anthropomorphic phantom. MOSkinTM dosimeters were placed within the phantom to measure absorbed point organ doses for 2 commonly applied clinical scan protocols, namely the renal calculus scan and the pulmonary embolus scan. Measured organ doses in the imaged field of view were found to be in the dose range 4.7-9.5 mGy and 16.2-27.4 mGy for the renal calculus scan and pulmonary scan protocols respectively. For the derivation of effective dose, using the more recent ICRP 103 tissue weighting factors (w T) compared to that of the ICRP 60 wT resulted in a difference in the derived effective dose by up to 0.8 mSv (-20%) in the renal calculus protocol and up to 1.8 mSv (18%) in the pulmonary embolus protocol. This difference is attributed to the reduced radiosensitivity of the gonads and the increased radiosensitivity of breast tissue in the latest ICRP 103 assigned wT. The results of this study show that the MOSkinTM dosimeter is a useful real-time tool for the direct assessment of organ doses in clinical MSCT examinations. © 2012 Elsevier Ltd. All rights reserved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effective radiation dose of a MSCT, two CBCT and one conventional radiography device in the ankle region

BACKGROUND The aim of this study was to assess and compare the effective doses (ICRP 103) in the ankle region of X-ray imaging resulting from a multi slice computed tomography (MSCT) device, two cone beam CT (CBCT) devices and one conventional x-ray device. METHODS Organ dose measurements were performed using 20 metal oxide field effect transistor (MOSFET) dosimeters that were placed in a cus...

متن کامل

Organ Dose Measurement in Computed Tomography Using Thermoluminescence Dosimeter in Locally Developed Phantoms

Introduction: Organ dose estimation using thermoluminescence dosimeter (TLD) is known to be a standard, although many other methods, such as simulation software, optically stimulated luminescent dosimeters, and photodiodes are still in use. This study aimed at directly measuring mean organ doses to the selected organs in the head/neck, chest, and abdominal regions from four computed tomography ...

متن کامل

Methods for monitoring patient dose in dental radiology.

Different types of X-ray equipment are used in dental radiology, such as intra-oral, panoramic, cephalometric, cone-beam computed tomography (CBCT) and multi-slice computed tomography (MSCT) units. Digital receptors have replaced film and screen-film systems and other technical developments have been made. The radiation doses arising from different types of examination are sparsely documented a...

متن کامل

Establishment of Diagnostic Reference Levels and Estimation of Effective Dose from Computed Tomography Head Scans at a Tertiary Hospital in South Africa

Introduction: Head scans are the most frequently performed computed tomography (CT) examinations worldwide. However, there is growing concern over the probability of increased cancer risks among the exposed populations. Diagnostic reference levels (DRLs) identify radiation dose that is not commensurate with clinical objectives. The aim of this study was to establish DR...

متن کامل

A comparative evaluation of cone-beam computed tomography and multi-slice computed tomography in the diagnosis of sheep mandibular bone defect: an in vitro study

Introduction: Diagnosis of lesions and bone defects is very important and there is a lack of substantial studies on the most appropriate method for bone defect measurement. Hence, the aim of this study is to evaluate the accuracy of multi-slice computed tomography (MSCT) and cone-beam computed tomography (CBCT) in the diagnosis of mandibular bone defects present in sheep. Material & Methods: T...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016