Prescriptive patient extracorporeal circuit and oxygenator sizing reduces hemodilution and allogeneic blood product transfusion during adult cardiac surgery.

نویسندگان

  • Shahna L Bronson
  • Jeffrey B Riley
  • Joshua P Blessing
  • Mark H Ereth
  • Joseph A Dearani
چکیده

UNLABELLED The goal of this cardiopulmonary bypass (CPB) quality improvement initiative was to maximize hemoglobin nadir concentration by minimizing hemodilution and, in turn, eliminating allogeneic blood product transfusion. The effects of transitioning from "one-size-fits-all" to "right-sized" oxygenators, reservoirs, and arterial-venous tubing loops were evaluated through a 2-year retrospective review of 3852 patient perfusion records. Using a sizing algorithm, derived from manufacturers' recommendations, we were able to create individualized "right-sized" extracorporeal circuits based on patient body surface area, cardiac index, and target blood flows. Use of this algorithm led to an increase in the percent of algorithm-recommended smaller oxygenators being used from 39% to 63% (p < .01) and an increase in average hemoglobin nadir from 8.38 to 8.76 g/dL (p < .01). Decreased priming volumes led to increased hemoglobin nadir and decreases in allogeneic blood transfusion (p = .048). Patients with similar body surface areas who previously were exposed to larger oxygenators, reservoirs, and arterial-venous loops were now supported with smaller circuits as a result of the use of the right-sized algorithm. Adjustments to the algorithm were made for unique patients and procedural situations including age, gender, and length and type of procedure. Larger heat exchanger surface area oxygenators were used for circulatory arrest procedures as a result of the need for increased heat exchange capability. Despite the generally higher costs of smaller circuits, reduced transfusion-related expenditures and decreased exposure risks justify the use of smaller circuit components. This quality improvement initiative demonstrated that as an integral part of a multidisciplinary, multimodal blood conservation effort, the use of the "right-sized" circuit algorithm can help to elevate hemoglobin nadir during CPB and eliminate allogeneic blood transfusions to patients undergoing CPB. KEYWORDS cardiopulmonary bypass, oxygenator, perfusion index, extracorporeal circuit, hemodilution.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Going beyond manufacturers' limitations is not in the best interest of our patients.

In your last issue, the Technique Article entitled “Prescriptive Patient Extracorporeal Circuit and Oxygenator Sizing Reduces Hemodilution and Allogeneic Blood Product Transfusion during Adult Cardiac Surgery: by Bronson et al. (JECT 2013;45:167–72), the authors and their cardiac program are to be congratulated on their quality initiative to address intraoperative hemodilution and their reducti...

متن کامل

Novel Applications of Modified Ultrafiltration and Autologous Priming Techniques to Reduce Blood Product Exposure on ECMO.

Patients needing the assistance of extracorporeal membrane oxygenation (ECMO) are at risk of hemodilution and, in some instances, may require exposure to large amounts of allogeneic blood products. Patient outcomes can be improved by taking steps to reduce transfusions and hemodilution. Currently, modified ultrafiltration (MUF) is used across the world to reduce hemodilution after cardiopulmona...

متن کامل

Evaluation of Retrograde Autologous Priming (RAP) effect on Hemodilution and transfusion rate in operation room and ICU

Abstract Background and Objectives To perform open heart surgery, the patient needs to be placed on the bypass system. This initial volume causes excessive dilution of the patient's blood and the use of blood products, which can alter the surgical procedure and recovery of the patient. The purpose of this study was to evaluate the usefulness of performing a retrograde autologous prime to reduc...

متن کامل

A technique for autologous priming of the veno-venous bypass circuit during liver transplantation.

Orthotopic liver transplantations (OLT) have been associated with significant blood loss and hemodilution, necessitating significant homologous blood component replacement. Increasing administration of homologous blood products has been found to be inversely related to patient and graft survival. Various methods to reduce the amount of blood products patients receive during OLT, such as antifib...

متن کامل

Autologous priming technique to reduce blood transfusion in pediatric cardiopulmonary bypass.

Excessive hemodilution during cardiopulmonary bypass is associated with decreased oxygen carrying capacity, edema, and organ dysfunction. The use of blood products is often necessary to prime the extracorporeal circuit for pediatric cardiac surgical patients. However, the use of blood products carries serious risks both in the acute and long-term aspects of patient care. Autologous priming of t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The journal of extra-corporeal technology

دوره 45 3  شماره 

صفحات  -

تاریخ انتشار 2013