Vectorcardiography for Optimization of Stimulation Intervals in Cardiac Resynchronization Therapy

نویسندگان

  • Caroline J. M. van Deursen
  • Liliane Wecke
  • Wouter M. van Everdingen
  • Marcus Ståhlberg
  • Michel H. G. Janssen
  • Frieder Braunschweig
  • Lennart Bergfeldt
  • Harry J. G. M. Crijns
  • Kevin Vernooy
  • Frits W. Prinzen
چکیده

Current optimization of atrioventricular (AV) and interventricular (VV) intervals in cardiac resynchronization therapy (CRT) is time consuming and subject to noise. We aimed to prove the principle that the best hemodynamic effect of CRT is achieved by cancelation of opposing electrical forces, detectable from the QRS morphology in the 3D vectorcardiogram (VCG). Different degrees of left (LV) and right ventricular (RV) pre-excitation were induced, using variation in AV intervals during LV pacing in 20 patients with left bundle branch block (LBBB) and variation in VV intervals during biventricular pacing in 18 patients with complete AV block or atrial fibrillation. The smallest QRS vector area identified stimulation intervals with minimal systolic stretch (median difference [IQR] 20 ms [-20, 20 ms] and maximal hemodynamic response (10 ms [-20, 40 ms]). Reliability of VCG measurements was superior to hemodynamic measurements. This study proves the principle that VCG analysis may allow easy and reliable optimization of stimulation intervals in CRT patients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Vectorcardiography as a tool for easy optimization of cardiac resynchronization therapy in canine left bundle branch block hearts.

BACKGROUND In cardiac resynchronization therapy (CRT), optimization of left ventricular (LV) stimulation timing is often time consuming. We hypothesized that the QRS vector in the vectorcardiogram (VCG) reflects electric interventricular dyssynchrony, and that the QRS vector amplitude (VAQRS), halfway between that during left bundle branch block (LBBB) and LV pacing, reflects optimal resynchron...

متن کامل

Impedance cardiography: a useful and reliable tool in optimization of cardiac resynchronization devices.

AIMS Optimizing cardiac resynchronization therapy (CRT) devices has become more complex since modification of both atrioventricular (AV) and interventricular (VV) stimulation intervals has become possible. The current paper presents data from the routine use of impedance cardiography (IC)-based cardiac output (CO) measurements to guide the optimization of AV- and VV-interval timing of CRT devic...

متن کامل

Measurement precision in the optimization of cardiac resynchronization therapy.

BACKGROUND Cardiac resynchronization therapy improves morbidity and mortality in appropriately selected patients. Whether atrioventricular (AV) and interventricular (VV) pacing interval optimization confers further clinical improvement remains unclear. A variety of techniques are used to estimate optimum AV/VV intervals; however, the precision of their estimates and the ramifications of an impr...

متن کامل

Enhancing Response in the Cardiac Resynchronization Therapy Patient The 3B Perspective—Bench, Bits, and Bedside

Cardiac resynchronization therapy (CRT) is an established nonpharmacological treatment for patients with heart failure (HF), reduced left ventricular (LV) ejection fraction, and a wide QRS complex. Although the therapy was developed 30 years ago and approved by the Food and Drug Administration in 2001, attempts to improve it have never stopped. Such improvements have been facilitated by combini...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2015