Continuous analysis of dye-loaded, single cells on a microfluidic chip.

نویسندگان

  • K Scott Phillips
  • Hsuan Hong Lai
  • Emily Johnson
  • Christopher E Sims
  • Nancy L Allbritton
چکیده

Continuous analysis of two dyes loaded into single mammalian cells using laser-based lysis combined with electrophoretic separation was developed and characterized on microfluidic chips. The devices employed hydrodynamic flow to transport cells to a junction where they were mechanically lysed by a laser-generated cavitation bubble. An electric field then attracted the analyte into a separation channel while the membranous remnants passed through the intersection towards a waste reservoir. Phosphatidylcholine (PC)-supported bilayer membrane coatings (SBMs) provided a weakly negatively charged surface and prevented cell fouling from interfering with device performance. Cell lysis using a picosecond-pulsed laser on-chip did not interfere with concurrent electrophoretic separations. The effect of device parameters on performance was evaluated. A ratio of 2 : 1 was found to be optimal for the focusing-channel : flow-channel width and 3 : 1 for the flow-channel : separation-channel width. Migration times decreased with increased electric field strengths up to 333 V cm(-1), at which point the field strength was sufficient to move unlysed cells and cellular debris into the electrophoretic channel. The migration time and full width half-maximum (FWHM) of the peaks were independent of cell velocity for velocities between 0.03 and 0.3 mm s(-1). Separation performance was independent of the exact lysis location when lysis was performed near the outlet of the focusing channel. The migration time for cell-derived fluorescein and fluorescein carboxylate was reproducible with <10% RSD. Automated cell detection and lysis were required to reduce peak FWHM variability to 30% RSD. A maximum throughput of 30 cells min(-1) was achieved. Device stability was demonstrated by analyzing 600 single cells over a 2 h time span.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Microfluidic selection and retention of a single cardiac myocyte, on-chip dye loading, cell contraction by chemical stimulation, and quantitative fluorescent analysis of intracellular calcium.

A microfluidic method to study the contraction of a single cardiac myocyte (heart muscle cell) has been developed. This method integrates various single-cell operations as well as on-chip dye loading, and quantitative analysis of intracellular calcium concentration, [Ca2+]i. After the channel enlargement by on-chip etching to accommodate large-sized cardiac myocytes, a single cell is selected a...

متن کامل

Fluorescent Contrast agent Based on Graphene Quantum Dots Decorated Mesoporous Silica Nanoparticles for Detecting and Sorting Cancer Cells

Background and Objectives: The inability of classic fluorescence-activated cell sorting to single cancer cell sorting is one of the most significant drawbacks of this method. The sorting of cancer cells in microdroplets significantly influences our ability to analyze cancer cell proteins. Material and Methods: We adapted a developed microfluidic device as a 3D in vitro model to sorted MCF-7 c...

متن کامل

Optofluidic Dye Lasers

Optofluidic dye lasers refer to a class of liquid dye lasers, usually on a microfabricated device, in which the adaptive nature of the liquid gain medium allows the dynamical control of the laser properties. Miniaturizing liquid dye lasers onto a microfluidic device not only results in compact, easy-to-maintain and safe dye laser systems, but also provides unprecedented optical performances suc...

متن کامل

A simple PDMS-based microfluidic channel design that removes bubbles for long-term on-chip culture of mammalian cells.

This report shows methods to fabricate polydimethylsiloxane (PDMS) microfluidic systems for long-term (up to 10 day) cell culture. Undesired bubble accumulation in microfluidic channels abruptly changes the microenvironment of adherent cells and leads to the damage and death of cells. Existing bubble trapping approaches have drawbacks such as the need to pause fluid flow, requirement for extern...

متن کامل

Artery-on-a-chip platform for automated, multimodal assessment of cerebral blood vessel structure and function.

We present a compact microfluidic platform for the automated, multimodal assessment of intact small blood vessels. Mouse olfactory artery segments were reversibly loaded onto a microfluidic device and kept under physiological (i.e., close to in vivo) environmental conditions. For immunohistochemical endpoint protein analysis, automated on chip fixation and staining of the artery eliminated the ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Lab on a chip

دوره 11 7  شماره 

صفحات  -