Novel Compression Tool to Prevent Hematomas and Skin Erosions After Device Implantation.
نویسندگان
چکیده
BACKGROUND The incidence of hematoma formation following implantation of a cardiovascular implantable electronic device (CIED) is estimated to be 5% even if a pressure dressing is applied. It is unclear whether a pressure dressing can really compress the pocket in different positions. Furthermore, the adhesive tape for fixing pressure dressings can tear the skin. We developed a new compression tool for preventing hematomas and skin erosions. METHODS AND RESULTS We divided 46 consecutive patients receiving anticoagulation therapy who underwent CIED implantation into 2 groups (Group I: conventional pressure dressing, Group II: new compression tool). The pressure on the pocket was measured in both the supine and standing positions. The incidence of hematomas was compared between the 2 groups. The pressure differed between the supine and standing positions in Group I, but not in Group II (Group I: 14.8±7.1 mmHg vs. 11.3±9.9 mmHg, P=0.013; Group II: 13.5±2.8 mmHg vs. 13.5±3.5 mmHg, P=0.99). The incidence of hematomas and skin erosions was documented in 2 (8.7%) and 3 (13%) Group I patients, respectively. No complications were documented in Group II. CONCLUSIONS The new compression tool can provide adequate continuous pressure on the pocket, regardless of body position. This device may reduce the incidence of hematomas and skin erosions after CIED implantation.
منابع مشابه
An Unusual Case of a Large Hematorrachis Associated with Multi-Level Osteoporotic Vertebral Compression Fractures; a Case Report
Spinal epidural haemorrhage may present as back pain associated with radicular symptoms and can be a catastrophic clinical scenario with progression to paraplegia or even sudden death. Being a rare entity, it needs a high index ofclinical suspicion to diagnose it. Fractures have been documented as a cause of hematorrachis but such hematomas only extend to one or two vertebral segments. Large ep...
متن کاملIntermuscular pocket for subcutaneous implantable cardioverter defibrillator: Single-center experience
The subcutaneous implantable cardioverter defibrillator (S-ICD) is a novel device now accepted in clinical practice for treating ventricular arrhythmias. In 14 consecutive patients, S-ICD devices were placed in the virtual space between the anterior surface of the serratus anterior muscle and the posterior surface of the latissimus dorsi muscle. During a mean follow up of 9 months, no dislocati...
متن کاملImplantable cardioverter-defibrillator in a patient with dextrocardia situs inversus
Background: Dextrocardia is a congenital anomaly, which may have coexistent coronary artery disease (CAD), arrhythmias and conventional indications for device therapy. However, the implantation of transvenous leads can be technically challenging and the approach needs to be tailored to the patient's individual anatomy. Case presentation: A 54-year-old male with dextrocardia situs inversus and i...
متن کاملSubdural Thoracolumbar Spine Hematoma after Spinal Anesthesia: A Rare Occurrence and Literature Review of Spinal Hematomas after Spinal Anesthesia
Spinal hematomas are a rare but serious complication of spinal epidural anesthesia and are typically seen in the epidural space; however, they have been documented in the subdural space. Spinal subdural hematomas likely exist within a traumatically induced space within the dural border cell layer, rather than an anatomical subdural space. Spinal subdural hematomas present a dangerous clinical s...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation journal : official journal of the Japanese Circulation Society
دوره 79 8 شماره
صفحات -
تاریخ انتشار 2015