Detection and three-dimensional visualization of lesion models using Sonoelastography
نویسندگان
چکیده
Sonoelastography is a vibration Doppler technique for imaging the relative elasticity of tissues. Detectability of hard lesions of various sizes has previously been demonstrated in tissue phantoms by our group. Because real tissue differs from phantom material, the injection of formaldehyde in fresh liver tissue is being used as an in-vitro lesion model. Pieces of fresh calf liver were embedded in an agar gel then injected with a bolus of 37% formaldehyde to create a stiff lesion. Two and three-dimensional sonoelastography and b-mode images were acquired. The lesions were visible in each sonoelastography image as a region of reduced vibration. After imaging, lesions were dissected and measured for size and volume. One 0.4 cc bolus injection of formaldehyde created a lesion with a volume of 10.3 cc in the sonoelastography image compared to 9.3 cc using fluid displacement of the dissected lesion. A 0.33 cc injection of formaldehyde lesion created a volume of 5 cc in the sonoelastography image compared to 4.4 cc using fluid displacement. Sonoelastography imaging techniques for imaging hard lesions in phantoms can be successfully extended to imaging formaldehyde induced lesions in real tissue.
منابع مشابه
Three-dimensional sonoelastography: principles and practices.
Sonoelastography is an ultrasound imaging technique where low amplitude, low-frequency shear waves (less than 0.1 mm displacement and less than 1 kHz frequency) are propagated through internal organs, while real-time Doppler techniques are used to image the resulting vibration pattern. When a discrete hard inhomogeneity, such as a tumour, is present within a region of soft tissue, a decrease in...
متن کاملProstate Cancer Detection Based on Three Dimensional Sonoelastography
In this paper, we evaluate the performance of sonoelastography for prostate cancer detection. Ultrasound (US) B-mode and sonoelastographic volumes were acquired from five prostate glands ex vivo. Additionally, one more gland was imaged in vivo using a transrectal US probe. Semi-automatic algorithms were used to segment the surface of the gland from the B-mode volume and the tumors from sonoelas...
متن کاملProstate cancer: three-dimensional sonoelastography for in vitro detection.
PURPOSE To prospectively evaluate the accuracy of three-dimensional (3D) sonoelastographic imaging, relative to that of gray-scale ultrasonography (US), in the in vitro detection of prostate cancer. MATERIALS AND METHODS The study was approved by the institutional review board and was HIPAA compliant. Informed consent was obtained from all patients. Nineteen prostatectomy specimens from patie...
متن کاملThree-dimensional color Doppler ultrasonography of the kidney vasculature in normal dogs
Three-dimensional color Doppler ultrasonography is a new technique to evaluate the pattern of blood vessels. This study was performed to assess the feasibility of this method in evaluation of kidney vasculature pattern in dogs. In this paper, visualization of the Renal, Interlobar, Arcuate, and interlobular arteries and veins using 3D color Doppler ultrasonography in dogs is shown and the techn...
متن کاملVibration sonoelastography and the detectability of lesions.
Vibration sonoelastography has been developed for the detection of hard lesions in relatively soft tissue. The basic concept is to propagate low-amplitude and low-frequency shear waves (with displacements below 0.1 mm and frequencies typically below 1000 Hz) through deep organs, and displaying the vibration response in real-time using advanced color Doppler imaging techniques. A hard inhomogene...
متن کامل