Breast Positioning during Mammography: Mistakes to be Avoided
نویسندگان
چکیده
AIMS AND OBJECTIVES Breast positioning is the key factor affecting a mammogram. If care is taken during positioning, it maximizes the amount of breast tissue being imaged, eliminates most of the artifacts, and increases sensitivity of the mammogram. This retrospective study was carried out in our department to assess correctness, and also the incorrectness of breast positioning, which need to be avoided to obtain an ideal mammogram. MATERIAL AND METHODS A total of 1369 female patients were included in this study. Mammography was performed on full field detector digital mammography equipment. Craniocaudal (CC) view and mediolateral oblique (MLO) view were carried out for each breast. Four views were done for 1322 patients. The remaining 47 patients had undergone a mastectomy and underwent two views for the other breast. Mistakes in improperly positioned mammogram were assessed with respect to proper visualization of nipple, position of pectoralis major, pectoral-nipple distance (PND), inframammary fold, and adequate coverage of all breast quadrants. RESULTS As per prescribed guidelines, mistakes in positioning were recognized in 2.879% of total mammograms. Improper positioning of the nipple was the commonest problem, seen in 3.827% of mammograms, CC view. On MLO view, bilaterally, pectoralis shadow was not seen in 0.520% mammograms, its margin was not straight/convex in 0.706%, lower edge of pectoralis was above pectoralis-nipple line in 2.081%, and inframammary fold was not seen in 1.189%. There was inadequate coverage of lower quadrants in 2.787%, and mismatch in PND was seen in 3.864%. In few of the patients, the shortcomings as a result of improper positioning were noted on one view, the rest being normal. CONCLUSION Positioning is the most important factor affecting the resultant mammography image. During mammography, many cases are improperly positioned and as a result the examination is inconclusive, which reduces the sensitivity of mammography.
منابع مشابه
Procedures and documentation for mammography and quality management
Mammography is currently the most effective noninvasive means of imaging the breast. Initially developed as a diagnostic aid to evaluate clinically detected breast abnormalities, mammography has evolved to be a widely used method to screen occult breast cancers in asymptomatic women. During the past 20 years, there has been substantial advancement in this field, in terms of image quality and re...
متن کاملLateral Decubitus Positioning Stereotactic Vacuum-Assisted Breast Biopsy with True Lateral Mammography
Stereotactic vacuum-assisted breast biopsy (VAB) has been used to evaluate microcalcifications or non-palpable breast lesions on mammography. Although stereotactic VAB is usually performed in a prone or upright position, an expensive prone table is necessary and vasovagal reactions often occur during the procedure. For these reasons, the lateral decubitus position can be applied for stereotacti...
متن کاملQuantification of the Pain and Physical Burden Experienced during Positioning for Craniocaudal Imaging in Mammography, Evaluated by Measurement of Muscle Activity
Mammography is carried out in a special position, i.e. “an image is taken while the breast is compressed, stretched and kept in a fixed position”. The purpose of this study was to demonstrate quantitatively and qualitatively the physical and psychological burden due to positioning and breast compression during mammography. Muscle activity of each part of the body during positioning for the stan...
متن کاملFull Field Digital Mammography with Breast Cushions in Screening Subjects
To explore the impact of radiolucent breast cushions on breast pain and image quality of full field digital mammography (FFDM) in screening subjects. The American College of Radiology (ACR) phantom and fifty-four women were enrolled in this study. Use of cushions reduced pain (p < 0.001). The imaging quality with cushions was inferior to those without cushions in phantom studies (p ≦ 0.01), on ...
متن کاملDesigning a shield to reduce radiation dose during mammography: Dosimetric evaluation
Background: This paper presents a method to reduce radiation exposure during mammography by analysing the doses to ipsilateral and contralateral breasts and to adjacent organs by evaluating material-dependent shielding performance. Materials and Methods: Six target-filter combinations (Mo-Mo, Mo-Rh, Rh-Rh, Rh-Mo, W-Mo, W-Rh) were tested by measuring the doses delivered to the breasts and adjac...
متن کامل