A comparison of two sphenoidotomy approaches using a novel computerized tomography grading system.

نویسندگان

  • Heitham Gheriani
  • David Flamer
  • Trent Orton
  • Brad Mechor
  • Amin R Javer
چکیده

BACKGROUND Endoscopic management of sphenoid sinus disease has great potential for surgical complications. A variety of endoscopic surgical techniques have been described for entering the sphenoid sinus. The utility of these surgical techniques is based on the position of the superior turbinate attachment to the sphenoid face (Parson's ridge). We introduce a novel computerized tomography (CT) grading system for the attachment of the superior turbinate to the sphenoid face. Using this new grading system, we recommend a safer systematic approach for entry into the sphenoid sinus. METHODS A grading based on the attachment of the superior turbinate to the sphenoid face at the level of the natural sphenoid ostium was developed. A total of 53 patients were enrolled. Types A, B, and C refer to the superior turbinate attachment at the medial, middle, or lateral third of the anterior sphenoid face, respectively, and type D refers to orbital attachment of the superior turbinate. The surgical approach used (superior turbinate intact [STI] or superior turbinate resection [STR]) was recorded and correlated to the type of superior turbinate attachment. RESULTS The overall incidence of the various superior turbinate attachments were 40% (41) for type A, 41% (42) for type B, 18% (19) for type C, and 1% (1) for type D. STR was used in 38 sides (44%) and STI was used in 48 sides (56%). Spearman correlation study showed that the closer the superior turbinate attachment was to the orbit the more likely STR was used as the choice of entry into the sphenoid (p < 0.001). CONCLUSION To perform a safe sphenoid entry it is pertinent to evaluate the superior turbinate attachment to the sphenoid face before making a decision on the method of entry.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Validation of a grading system for the attachment of the superior turbinate to the sphenoid face.

BACKGROUND The attachment of the superior turbinate to the sphenoid face may be an important factor in determining the approach for sphenoidotomy. We sought to validate a previously described 4-type grading system for superior turbinate attachment (Type: A, within its medial one-third; B, in its middle one-third; C, to its lateral one-third; and D, directly to the orbit) to the face of the sphe...

متن کامل

Comparison between Needle Biopsy under Guide of Conventional Computerized Tomography (CCT) and Fluoroscopic Computerized Tomography (FCT) in Abdominal, Mediastinal, Lung, Pelvic, Bone, and Liver Masses

Background and Objective: Computerized tomography and fluoroscopic computerized tomography are amongst the methods used for guiding needle biopsy processes; however, fluoroscopic computerized tomography demonstrates the images during the process of biopsy. This study aims to compare and contrast the success of biopsy under guide...

متن کامل

The Accuracy of Cone-beam Computerized Tomography Linear Measurements in Human Dry Mandible

Background & Aims: The aim of this study was to evaluate the accuracy of Cone-beam Computerized Tomography (CBCT) linear measurements in dry mandibles by comparing them with direct measurements. Methods: Two human dry mandibles were used in this study. Thirteen sites were selected on each mandible. Specimens were scanned by CBCT and linear measurements were made using Planmeca Romexis 2.3.0.R s...

متن کامل

Comparison of state-of-the-art atlas-based bone segmentation approaches from brain MR images for MR-only radiation planning and PET/MR attenuation correction

Introduction: Magnetic Resonance (MR) imaging has emerged as a valuable tool in radiation treatment (RT) planning as well as Positron Emission Tomography (PET) imaging owing to its superior soft-tissue contrast. Due to the fact that there is no direct transformation from voxel intensity in MR images into electron density, itchr('39')s crucial to generate a pseudo-CT (Computed Tomography) image ...

متن کامل

Evaluation of performance quality of SPECT camera in Shariati Hospital of Tehran University of Medical Sciences [Persian]

In nuclear medicine, there are two methods of imaging, planar and tomography. Single photon emission computerized tomography (SPECT) shows better image details and therefore is influenced more by image parameters such as resolution, uniformity, sensitivity, etc. Manufacturers provide customers with data which are obtained by complicated and sometimes secret methods. Marketing companies te...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of rhinology & allergy

دوره 23 2  شماره 

صفحات  -

تاریخ انتشار 2009