Stability-indicating HPLC method for simultaneous determination of clidinium bromide and chlordiazepoxide in combined dosage forms.

نویسندگان

  • Ashutosh Pathak
  • Pallavi Rai
  • Sadhana J Rajput
چکیده

The study describes development and subsequent validation of a stability indicating reverse-phase high-performance liquid chromatography method for the simultaneous estimation of clidinium bromide (CLI) and chlordiazepoxide (CHLOR) from their combination drug product. Chromatographic separations are performed at ambient temperature on a Phenomenex Luna C(18) (250 mm x 4.6 mm, i.d., 5 microm) column using a mobile phase consisting of potassium dihydrogen phosphate buffer (0.05 M, pH 4.0 adjusted with 0.5% orthophosphoric acid)-methanol- acetonitrile (40:40:20, v/v/v). The flow rate is 1.0 mL/min, and the detection wavelength is 220 nm. The method is validated with respect to linearity, precision, accuracy, system suitability, and robustness. The utility of the procedure is verified by its application to marketed formulations that were subjected to accelerated degradation studies. The method distinctly separated the drug and degradation products even in actual samples. The products formed in marketed tablet dosage forms are similar to those formed during stress studies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simultaneous Determination of Clidinium Bromide and Chlordiazepoxide in Combined Dosage Forms by High-Performance Liquid Chromatography

A sensitive and precise RP-HPLC method has been developed for the simultaneous estimation of clidinium bromide (CDB) and chlordiazepoxide (CDZ) in pure and pharmaceutical formulations. The separation was achieved on a Nucleodur C8 (250 × 4.6 mm i.d., 5 μm particle size) column at 25°C. CH3CN-MeOH-NH4OAc 0.1M (30 : 40 : 30, v/v/v) was used as the mobile phase at a flow rate of 1.0 mL min(-1) and...

متن کامل

A New Stability Indicating RP-HPLC Method Development and Validation for the Simultaneous Estimation of Dolutegravir and Rilpivirine in Bulk and its Dosage Forms

A New Stability Indicating RP-HPLC Method Development and Validation for the Simultaneous Estimation of Dolutegravir and Rilpivirine in Bulk and its Dosage Forms. Abstract The objective of the work is to develop and validate a new, simple, highly sensitive, stability indicating RP-HPLC method for simultaneous estimation of Dolutegravir and Rilpivirine in bulk and its dosage f...

متن کامل

A Stability Indicating HPLC Method for the Determination of Fluvoxamine in Pharmaceutical Dosage Forms

Fluvoxamine maleate is a selective serotonin reuptake inhibitor, which is used for the treatment of different types of depressive disorders. In the present study, a stability indicating HPLC method was developed and validated for the determination of fluvoxamine maleate. The chromatographic separation was carried out using a Nova-Pak CN column and a mixture of K2HPO4 50 mM (pH 7.0) and acetonit...

متن کامل

A Stability Indicating HPLC Method for the Determination of Fluvoxamine in Pharmaceutical Dosage Forms

Fluvoxamine maleate is a selective serotonin reuptake inhibitor, which is used for the treatment of different types of depressive disorders. In the present study, a stability indicating HPLC method was developed and validated for the determination of fluvoxamine maleate. The chromatographic separation was carried out using a Nova-Pak CN column and a mixture of K2HPO4 50 mM (pH 7.0) and acetonit...

متن کامل

A Rapid, Stability-Indicating RP-HPLC Method for the Simultaneous Determination of Formoterol Fumarate, Tiotropium Bromide, and Ciclesonide in a Pulmonary Drug Product

A stability-indicating reversed-phase high performance liquid chromatography (RP-HPLC) method was developed for the simultaneous determination of Formoterol fumarate (FOR), Tiotropium bromide (TRI), and Ciclesonide (CLS) in a pulmonary drug product. The desired chromatographic separation was achieved on the Zorbax SB C8, 5 μm (150 × 4.6 mm) column, using gradient elution at 230 nm detector wave...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of chromatographic science

دوره 48 3  شماره 

صفحات  -

تاریخ انتشار 2010