Accuracy of impressions with different impression materials in angulated implants.
نویسندگان
چکیده
PURPOSE To evaluate the dimensional accuracy of the resultant (duplicative) casts made from two different impression materials (polyvinyl siloxane and polyether) in parallel and angulated implants. MATERIALS AND METHODS Three definitive master casts (control groups) were fabricated in dental stone with three implants, placed at equi-distance. In first group (control), all three implants were placed parallel to each other and perpendicular to the plane of the cast. In the second and third group (control), all three implants were placed at 10° and 15 o angulation respectively to the long axis of the cast, tilting towards the centre. Impressions were made with polyvinyl siloxane and polyether impression materials in a special tray, using a open tray impression technique from the master casts. These impressions were poured to obtain test casts. Three reference distances were evaluated on each test cast by using a profile projector and compared with control groups to determine the effect of combined interaction of implant angulation and impression materials on the accuracy of implant resultant cast. RESULTS Statistical analysis revealed no significant difference in dimensional accuracy of the resultant casts made from two different impression materials (polyvinyl siloxane and polyether) by closed tray impression technique in parallel and angulated implants. CONCLUSION On the basis of the results of this study, the use of both the impression materials i.e., polyether and polyvinyl siloxane impression is recommended for impression making in parallel as well as angulated implants.
منابع مشابه
Effect of implant angulation, connection length, and impression material on the dimensional accuracy of implant impressions: an in vitro comparative study.
BACKGROUND With regard to implant-supported prostheses, to date no technique has been proven to guarantee a completely passive fit of prosthetic frameworks. Several clinical variables may affect the precision of impressions, particularly in the presence of implants. PURPOSE To compare the accuracy of implant impressions made with different materials, lengths of impression coping connections, ...
متن کاملبررسی مقایسهای تریهای قالبگیری تمام قوس و نیم قوس بر دقت ابعادی و زاویهای قالبهای تهیه شده از ایمپلنتهای زاویهدار
Background and Aims: Taking impression from angulated implants has always been a great challenge in clinic. In this regard, studies on sectional trays are very few. The aim of this study was to evaluate and compare the dimensional and angular accuracy of impressions using full arch and sectional trays. Materials and Methods: Four implants (4.3 × 12 mm) (Implantium, Dentium) were plac...
متن کاملThe Accuracy of Four Impression-making Techniques in Angulated Implants Based on Vertical Gap
Statement of the Problem Precision of the impression taken from implant positions significantly determines accurate fit of implant-supported prostheses. An imprecise impression may produce prosthesis misfit. Purpose This study aimed to evaluate the accuracy of four impression-making techniques for angulated implants by stereomicroscope through measuring the vertical marginal gaps between the ...
متن کاملCast accuracy obtained from different impression techniques at different implant angulations (in vitro study)
BACKGROUND Angulated implants may result in inaccurate impressions, and the impression technique may affect the accuracy of the definitive cast. This study was designed to compare the dimensional accuracy of casts obtained from three impression techniques for three definitive lower casts with implants at different angulations. METHODS Three Osseolink implants were placed in three reference mo...
متن کاملComparison of Different Impression Techniques When Using the All-on-Four Implant Treatment Protocol.
PURPOSE The aim of this in vitro study was to compare the accuracy of two different impression techniques for the All-on-Four implant therapy protocol. MATERIALS AND METHODS An acrylic resin analog for an edentulous maxilla with four internal connection implants (Replace Select, Nobel Biocare) was fabricated according to the All-on-Four protocol. A total of 40 impressions were made with diffe...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Nigerian journal of clinical practice
دوره 16 3 شماره
صفحات -
تاریخ انتشار 2013