Effectiveness of the EndoActivator System in removing the smear layer after root canal instrumentation.
نویسندگان
چکیده
INTRODUCTION Elimination of the smear layer after root canal instrumentation requires the use of irrigating solutions. This cleaning can be completed with passive ultrasonic or sonic irrigation. The aim of this study was to evaluate the effectiveness of the EndoActivator System in removing the smear layer after rotary root canal instrumentation, with and without a final flush of 17% ethylenediaminetetraacetic acid (EDTA) solution, in coronal, middle, and apical thirds. METHODS Forty single-canal teeth were decoronated and randomly divided into 4 groups (n = 10). The groups were instrumented by using Mtwo System. EndoActivator was used with a final rinse of 1 mL of 17% EDTA or 4% NaOCl for 1 minute. The roots were longitudinally split and were grooved in the coronal, middle, and apical thirds. Scanning electron microscopy digital photomicrographs at 400x were taken to evaluate the amount of smear layer in each third. RESULTS The NaOCl/EndoActivator group did not remove any smear layer of the root canal wall (100% in the coronal, middle, and apical thirds). In the groups that used 17% EDTA (with or without EndoActivator), the smear layer was eliminated completely (100%) in the coronal third, but the amount of removal was less in the other two thirds. The comparisons between NaOCl versus NaOCl/EndoActivator groups and EDTA/NaOCl versus EDTA/EndoActivator/NaOCl groups showed no significant differences in root canal thirds. CONCLUSIONS The EndoActivator System did not enhance the removal of smear layer as compared with conventional Max-I-Probe irrigation with NaOCl and EDTA.
منابع مشابه
A Comparative Evaluation of Smear Layer Removal Using Apical Negative Pressure (EndoVac), Sonic Irrigation (EndoActivator) and Er:YAG laser -An In vitro SEM Study
BACKGROUND This study aimed to compare the smear layer removing efficacy of the EndoActivator, EndoVac and Er:YAG laser in extracted mandibular premolars, at the apical, middle and coronal third of root canal, through scanning electron microscopy. MATERIAL AND METHODS 40 extracted mandibular premolars were decoronated to a standardized length of 12 mm. Specimens were shaped to ProTaper F4 siz...
متن کاملExtra oral comparison of smear layer removal from root canals when using phosphoric acid and RCprep–NaOCL: A SEM study
Extra oral comparison of smear layer removal from root canals when using phosphoric acid and RCprep–NaOCL: A SEM study Dr. M. Zare Jahromi * - Dr. MR. Malekipour ** - Dr. F. Sobhi *** *Assistant Professor of Endodontics Dept., Faculty of Dentistry, Khorasgan Islamic Azad University. **Assistant Professor of Operative Dentistry Dept., Faculty of Dentistry, Khorasgan Islamic Azad University. ***D...
متن کاملEx-vivo Smear Layer Removal Efficacy of Two Activated Irrigation Techniques After Reciprocating Instrumentation in Curved Canals
Introduction This study aimed to compare the effectiveness of two activated irrigation techniques in removing the smear layer after single-file reciprocating instrumentation in curved canals. Materials and Methods Sixty distobuccal roots of maxillary molars were standardized to create a closed system, and then instrumented using WaveOne Primary (Dentsply Maillefer, Ballaigues, Switzerland) in...
متن کاملSmear layer removal and canal cleanliness using different irrigation systems (EndoActivator, EndoVac, and passive ultrasonic irrigation): field emission scanning electron microscopic evaluation in an in vitro study.
INTRODUCTION The purpose of this study was to evaluate the effectiveness of different irrigating methods in removing the smear layer at 1, 3, 5, and 8 mm from the apex of endodontic canals. METHODS Sixty-five extracted single-rooted human mandibular premolars were decoronated to a standardized length of 16 mm. Specimens were shaped to ProTaper F4 (Dentsply Maillefer, Ballaigues, Switzerland) ...
متن کاملComparative Evaluation of Smear Layer and Debris on the Canal Walls prepared with a Combination of Hand and Rotary ProTaper Technique using Scanning Electron Microscope.
INTRODUCTION The effect of smear layer and debris on the success rate of endodontic treatment has not yet been definitely determined. So the present study was aimed to evaluate the amount of smear layer and debris on the canal walls prepared with a combination of hand and rotary ProTaper technique using NaOCl and ethylenediaminetetraacetic acid (EDTA) alternately as root canal irrigants using s...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of endodontics
دوره 36 2 شماره
صفحات -
تاریخ انتشار 2010