Wrist function recovers more rapidly after volar locked plating than after external fixation but the outcomes are similar after 1 year

نویسندگان

  • Maria K T Wilcke
  • Hassan Abbaszadegan
  • Per Y Adolphson
چکیده

BACKGROUND AND PURPOSE Promising results have been reported after volar locked plating of unstable dorsally displaced distal radius fractures. We investigated whether volar locked plating results in better patient-perceived, objective functional and radiographic outcomes compared to the less invasive external fixation. PATIENTS AND METHODS 63 patients under 70 years of age, with an unstable extra-articular or non-comminuted intra-articular dorsally displaced distal radius fracture, were randomized to volar locked plating (n = 33) or bridging external fixation. Patient-perceived outcome was assessed with the Disability of the Arm, Shoulder, and Hand (DASH) questionnaire and the Patient-Rated Wrist Evaluation (PRWE) questionnaire. RESULTS At 3 and 6 months, the volar plate group had better DASH and PRWE scores but at 12 months the scores were similar. Objective function, measured as grip strength and range of movement, was superior in the volar plate group but the differences diminished and were small at 12 months. Axial length and volar tilt were retained slightly better in the volar plate group. INTERPRETATION Volar plate fixation is more advantageous than external fixation, in the early rehabilitation period.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Locked volar plating for complex distal radius fractures: Patient reported outcomes and satisfaction

BACKGROUND Distal radius fractures are common. The increasing prevalence of osteoporosis contributes to frequently complex articular injuries sustained even after low energy falls. The best method of treating complex type C distal radius fractures is debated. Locked volar plating and external fixation are both widely used with good reported results. Measures of success are traditionally based o...

متن کامل

Bridging external fixation and supplementary Kirschner-wire fixation versus volar locked plating for unstable fractures of the distal radius: a randomised, prospective trial.

We performed a prospective, randomised trial to evaluate the outcome after surgery of displaced, unstable fractures of the distal radius. A total of 280 consecutive patients were enrolled in a prospective database and 88 identified who met the inclusion criteria for surgery. They were randomised to receive either bridging external fixation with supplementary Kirschner-wire fixation or volar-loc...

متن کامل

Unstable distal radial fractures treated with external fixation, a radial column plate, or a volar plate. A prospective randomized trial.

BACKGROUND Optimal surgical management of unstable distal radial fractures is controversial, and evidence from rigorous comparative trials is rare. We compared the functional outcomes of treatment of unstable distal radial fractures with external fixation, a volar plate, or a radial column plate. METHODS Forty-six patients with an injury to a single limb were randomized to be treated with aug...

متن کامل

Failure of volar locking plate fixation of an extraarticular distal radius fracture: A case report

BACKGROUND Volar locking plates provide significant structural stability to the distal radius. Failure of a volar locked plating is a rarely reported complication in the literature. CASE PRESENTATION A 40 year-old, obese female patient who presented with a displaced extraarticular distal radius fracture, underwent open reduction and internal fixation of the fracture using a volar locking plat...

متن کامل

Examination of the Pronator Quadratus Muscle during Hardware Removal Procedures after Volar Plating for Distal Radius Fractures

BACKGROUND It is not clear whether the pronator quadratus (PQ) muscle actually heals and provides a meaningful pronation force after volar plating for distal radius fractures (DRFs). We aimed to determine whether the length of the PQ muscle, which is dissected and then repaired during volar plating for a DRF, affects the forearm rotation strength and clinical outcomes. METHODS We examined 41 ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 82  شماره 

صفحات  -

تاریخ انتشار 2011