Prevention of central venous catheter-related bloodstream infection by use of an antiseptic-impregnated catheter. A randomized, controlled trial.

نویسندگان

  • D G Maki
  • S M Stolz
  • S Wheeler
  • L A Mermel
چکیده

BACKGROUND Bloodstream infection related to short-term use of noncuffed central venous catheters is a common and serious problem. Technologic innovations to reduce the risk for these infections are needed. OBJECTIVE To determine 1) the efficacy of a novel antiseptic catheter in preventing central venous catheter-related infection, 2) patient tolerance of this catheter, and 3) the sources of bloodstream infection originating from noncuffed, multilumen central venous catheters. DESIGN Randomized, controlled clinical trial. SETTING Medical-surgical intensive care unit of a 450-bed university hospital. PARTICIPANTS 158 adults scheduled to receive a central venous catheter; 403 catheters were studied. INTERVENTION Participants received either a standard triple-lumen polyurethane catheter or a catheter that was indistinguishable from the standard catheter and was impregnated with chlorhexidine and silver sulfadiazine. MEASUREMENTS Catheters were studied for colonization and catheter-related bloodstream infection at removal; local and systemic effects of catheters were assessed. The origin of each catheter-associated bloodstream infection was sought by culturing all potential sources (skin, catheter segments, hubs, and infusate) and confirmed by restriction-fragment DNA subtyping. RESULTS Antiseptic catheters were less likely to be colonized at removal than control catheters (13.5 compared with 24.1 colonized catheters per 100 catheters; relative risk, 0.56 [95% CI, 0.36 to 0.89]; P = 0.005) and were nearly fivefold less likely to produce bloodstream infection (1.0 compared with 4.7 infections per 100 catheters; 1.6 compared with 7.6 infections per 1000 catheter-days; relative risk, 0.21 [CI, 0.03 to 0.95]; P = 0.03). In the control group, 8 catheter-related bloodstream infections were caused by Staphylococcus aureus, gram-negative bacilli, enterococci, or Candida species; no infections with these organisms occurred in the antiseptic catheter group (P = 0.003). No adverse effects from the antiseptic catheter were seen, and none of the 122 isolates obtained from infected catheters in either group showed in vitro resistance to chlorhexidine-silver sulfadiazine. Cost-benefit analysis indicated that the antiseptic catheter should prove cost-beneficial if an institution's rate of catheter-related bacteremia with noncuffed central venous catheters is at least 3 infections per 1000 catheter-days). CONCLUSIONS The chlorhexidine-silver sulfadiazine catheter is well tolerated, reduces the incidence of catheter-related infection, extends the time that noncuffed central venous catheters can be safely left in place for the short term, and should allow cost savings.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cost-effectiveness of antiseptic-impregnated central venous catheters for the prevention of catheter-related bloodstream infection.

CONTEXT A recent randomized controlled trial and meta-analysis indicated that central venous catheters impregnated with an antiseptic combination of chlorhexidine and silver sulfadiazine are efficacious in reducing the incidence of catheter-related bloodstream infection (CR-BSI); however, the ultimate clinical and economic consequences of their use have not been formally evaluated. OBJECTIVE ...

متن کامل

Effect of a second-generation venous catheter impregnated with chlorhexidine and silver sulfadiazine on central catheter-related infections: a randomized, controlled trial.

BACKGROUND Central venous catheter-related infections are a significant medical problem. Improved preventive measures are needed. OBJECTIVE To ascertain 1) effectiveness of a second-generation antiseptic-coated catheter in the prevention of microbial colonization and infection; 2) safety and tolerability of this device; 3) microbiology of infected catheters; and 4) propensity for the developm...

متن کامل

Chlorhexidine-impregnated dressing for prevention of catheter-related bloodstream infection: a meta-analysis*.

OBJECTIVE To assess the efficacy of a chlorhexidine-impregnated dressing for prevention of central venous catheter-related colonization and catheter-related bloodstream infection using meta-analysis. DATA SOURCES Multiple computerized database searches supplemented by manual searches including relevant conference proceedings. STUDY SELECTION Randomized controlled trials evaluating the effic...

متن کامل

Efficacy of antiseptic-impregnated central venous catheters in preventing catheter-related bloodstream infection: a meta-analysis.

CONTEXT Central venous catheters impregnated with chlorhexidine and silver sulfadiazine have recently been introduced for the prevention of catheter-related infections. However, there remains some uncertainty regarding the efficacy of these catheters because of conflicting reports in the literature. OBJECTIVE To evaluate the efficacy of chlorhexidine-silver sulfadiazine-impregnated central ve...

متن کامل

Antiseptic-impregnated central venous catheters: their evaluation in burn patients.

Central venous catheter-related infections are an important source of morbidity and mortality in burn patients. Antiseptic impregnated catheters have been recommended to prevent infections related to central venous lines in high-risk patients who require short-term catheters. This prospective, randomized, and controlled study compared the efficacy of standard and antiseptic devices in reducing ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Annals of internal medicine

دوره 127 4  شماره 

صفحات  -

تاریخ انتشار 1997