PURPOSE To investigate the relationship between myopia and macular thickness, as measured by optical coherence tomography. METHODS A total of 143 normal subjects comprising 80 eyes with high myopia (spherical equivalent [SE] < -6.0 D), 37 eyes with low to moderate myopia (SE between -6.0 and -0.5 D), and 26 nonmyopic eyes (SE > -0.5 D) were analyzed in this cross-sectional study. Total average, foveal, and inner and outer average macular thicknesses measured by the StratusOCT (Carl Zeiss Meditec Inc., Dublin, CA) were compared among the three diagnostic groups. Associations between macular thickness and refractive error/axial length were evaluated by linear regression analysis. RESULTS The minimum foveal and average foveal (1-mm ring on the OCT retinal thickness map) thicknesses were significantly greater, and the outer ring macular (3-6-mm) thicknesses significantly lower in the high myopic eyes than in the low to moderate myopic and nonmyopic eyes. No significant difference was found in the inner ring (1-3-mm) macular thickness measurements among the groups. There was a positive correlation between the axial length and the average foveal thickness (r = 0.374, P < 0.001). Negative correlations were found between axial length and the average outer ring macular thickness (r= -0.471, P < 0.001) and total average macular thickness (r= -0.311, P < 0.001). CONCLUSIONS Retinal thickness is related to refractive error/axial length in normal subjects with regional variations in correlation within the 6-mm macular region. Analysis of macular thickness in the evaluation of macular diseases and glaucoma should be interpreted only in the context of refractive errors and the location of measurement.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Aqueous Levels of Pigment Epithelium-Derived Factor and Macular Choroidal Thickness in High Myopia

Purpose. To investigate the correlation between aqueous and serum levels of pigment epithelium-derived factor (PEDF) and macular choroidal thickness in high myopia patients, both with and without choroidal neovascularization (CNV). Methods. Serum and aqueous levels of PEDF were measured by enzyme-linked immunosorbent assay in 36 high myopia patients (36 eyes) with no CNV (non-CNV group), 14 hig...

متن کامل

Spectral- and time-domain optical coherence tomography measurements of macular thickness in young myopic eyes

PURPOSE To evaluate the variation in macular retinal thickness and volume in young Chinese myopic patients using time-domain optical coherence tomography (Stratus TD-OCT) and spectral-domain optical coherence tomography (Cirrus HD-OCT). METHODS Ninety-two eyes of 92 myopic subjects were recruited in this study. Based upon spherical equivalence (SE), subjects were divided into two groups: the ...

متن کامل

Quantification of Macular Vascular Density Using Optical Coherence Tomography Angiography and Its Relationship with Retinal Thickness in Myopic Eyes of Young Adults

Purpose To quantify macular vascular density using optical coherence tomography angiography (OCTA) and to investigate its relationship with retinal thickness in myopic eyes of young adults. Methods In this cross-sectional study, 268 myopic eyes without pathological changes were recruited and divided into three groups: mild myopia (n = 81), moderate myopia (n = 117), and high myopia (n = 70). ...

متن کامل

A prospective study of macular thickness in amblyopic children with unilateral high myopia.

PURPOSE To compare macular thickness of the normal fellow eye to that of the amblyopic eye using optical coherence tomography (OCT) in children with unilateral high myopia. Relationships between macular thickness and magnitude of myopic anisometropia, axial length, and visual acuity (VA) were investigated. METHODS Thirty-one children with a mean age of 9.56 years were recruited. Macular thick...

متن کامل

Correlation between Visual Acuity and Optical Coherence Tomography-Measured Retinal Thickness in Diabetic Macular Edema

Background and Objective: Diabetic macular edema (DME) is one of the common complications of diabetes which significantly accounts for preventable visual impairment and blindness. Central macular thickness (CMT) is a feature found in DME patients. This study aims to determine the relationship between optical coherence tomography (OCT)-measured CMT and visual acuity (VA) in patients with DME bef...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 48 1  شماره 

صفحات  -

تاریخ انتشار 2007