Intracoronary pressure and flow velocity with sensor-tip guidewires: a new methodologic approach for assessment of coronary hemodynamics before and after coronary interventions.
نویسندگان
چکیده
The use of miniaturized pressure and velocity sensors mounted on angioplasty guidewires allows the simultaneous measurement of coronary blood flow velocity and transstenotic pressure gradient, 2 parameters that, combined, should perfectly characterize stenosis hemodynamics. The aim of this article is assessment of the changes in coronary blood flow velocity observed with a Doppler-tipped angioplasty guidewire in 35 patients undergoing balloon angioplasty. We also report our initial experience in 16 patients with the combined use of sensor-tip pressure and Doppler guidewires, and we discuss the application of new methodologic approaches for the study of the coronary circulation allowed by these techniques, such as the instantaneous assessment of the flow velocity/pressure and pressure gradient/flow velocity relations. Before and after angioplasty, flow velocity measurements were obtained distal to the stenosis, both in baseline conditions and after intracoronary injection of 8-12.5 mg of papaverine. The Doppler guidewire was left in place during the dilation procedure and the Doppler signal was continuously recorded during balloon inflation and after deflation to monitor the development of collateral flow, the restoration of flow after balloon deflation, the phase of postocclusive reactive hyperemia, and, incidently, the development of flow-limiting complications. Merits and pitfalls of several flow velocity parameters (average peak velocity, coronary flow velocity reserve, diastolic/systolic velocity ratio), as well as of parameters derived from the combination of pressure and velocity measurements (transstenotic pressure gradient/flow velocity relation and instantaneous diastolic hyperemic flow velocity/pressure relation) were evaluated in 35 patients with, and 37 without, significant coronary stenoses.(ABSTRACT TRUNCATED AT 250 WORDS)
منابع مشابه
Clinical Cardiology Frontiers Reversal of Coronary Atherosclerosis
124. Fallavollitta JA, Brody A, Bunnell IL, Kumar K, Canty JM. Fast computed tomography detection of coronary calcification in the diagnosis of coronary artery disease: comparison with angiography in patients <50 years old. Circulation. 1994;89:285-290. 125. Serruys PW, DeMario C, Meneveau N, de Jaegere P, Strikwerda S, de Feyter PJ, Emanuelsson H. Intracoronary pressure and flow velocity from ...
متن کاملThe diastolic flow-pressure gradient relation in coronary stenoses in humans.
OBJECTIVES We assessed the feasibility and reproducibility of the instantaneous diastolic coronary flow velocity-pressure gradient relation to characterize different degrees of coronary stenoses. BACKGROUND Assessment of the hemodynamic significance of coronary stenoses can be difficult. Using sensor-tipped guidewires, various physiologic indexes can be determined in the catheterization labor...
متن کاملCoronary Artery Disease Simultaneous Intracoronary Velocity- and Pressure-Derived Assessment of Adenosine-Induced Collateral Hemodynamics in Patients With One- to Two-Vessel Coronary Artery Disease
METHODS In 50 patients with oneand two-vessel coronary artery disease (CAD) undergoing percutaneous transluminal coronary angioplasty (PTCA), collateral flow index (CFI, no unit) changes and vascular resistance index (R, cm/mm Hg) changes of the collateral (Rcoll) and the distal collateral receiving (R4) vessel in response to adenosine (140 mg/min/kg IV) were measured by intracoronary (i.c.) Do...
متن کاملDiagnostic accuracy of combined intracoronary pressure and flow velocity information during baseline conditions: adenosine-free assessment of functional coronary lesion severity.
BACKGROUND The assessment of functional coronary lesion severity using intracoronary physiological parameters such as coronary flow velocity reserve and the more widely used fractional flow reserve relies critically on the establishment of maximal hyperemia. We evaluated the diagnostic accuracy of the stenosis resistance index during nonhyperemic conditions, baseline stenosis resistance index, ...
متن کاملSingle-wire pressure and flow velocity measurement to quantify coronary stenosis hemodynamics and effects of percutaneous interventions.
BACKGROUND Lack of high-fidelity simultaneous measurements of pressure and flow velocity distal to a coronary artery stenosis has hampered the study of stenosis pressure drop-velocity (DeltaP-v) relationships in patients. METHODS AND RESULTS A novel 0.014-inch dual-sensor (pressure and Doppler velocity) guidewire was used in 15 coronary lesions to obtain per-beat averages of pressure drop and...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The American journal of cardiology
دوره 71 14 شماره
صفحات -
تاریخ انتشار 1993