Magnetic Resonance Findings at 3 Tesla in Brown Syndrome.
نویسندگان
چکیده
An adolescent girl with prior right lower eyelid epiblepharon repair was referred to a tertiary care center for assessment of ipsilateral Brown syndrome. She was initially diagnosed 3 years previously and had been observed without treatment or report of bothersome symptoms. Clinical examination noted normal visual acuity and expected decreased orbital elevation with adduction. On a 3 Tesla magnetic resonance imaging study, axial (Figure 1A) and coronal (Figure 1B) fat-suppressed, post-contrast T1 imaging revealed asymmetric enlargement and enhancement of the right superior oblique tendon (arrows). Coronal T2 fat-suppressed imaging of both orbits (Figure 1C) and coned-down coronal T2 of the right orbit likewise demonstrated asymmetric signal in the superior oblique tendon (Figures 1C-1D; arrow), as well as patchy intensity in the surrounding superior orbit (Figure 1D; dashed arrow). The appearance suggests focal inflammation anterior to the trochlea as the imaging correlate of the clinically apparent Brown syndrome. First described as superior oblique tendon sheath syndrome in 1950,1 its imaging appearance has been documented in few case reports and small series.2,3 However, most studies include computed tomography or lower field strength magnetic resonance imaging examinations. The exquisite 3 Tesla, multiplanar, fat-suppressed imaging presented herein represents a unique and informative visualization of the anatomic features and pathologic appearance of the process.
منابع مشابه
Diffusion tensor tractography demonstration of partially injured spinal cord tracts in a patient with posttraumatic Brown Sequard syndrome.
The authors report the utility of diffusion tensor tractography in demonstrating the partially severed spinal cord tracts on one side with normal, intact, distally traceable tracts on the opposite side in a patient with posttraumatic Brown Sequard syndrome. A 30-year-old man presented with typical clinical features of a hemisection injury of the thoracic spinal cord, 2 months after he had susta...
متن کاملMagnetically programmable shunt valve: MRI at 3-Tesla.
A magnetically programmable cerebrospinal fluid (CSF) shunt valve (Codman Hakim Programmable Valve, Codman, a Johnson & Johnson Company, Raynham, MA) was assessed for magnetic field interactions, heating, artifacts and functional changes at 3-Tesla. The programmable valve showed minor magnetic field interactions and heating (+0.4 degrees C). Artifacts were relatively large in relation to the si...
متن کاملIn vivo differentiation of N-acetyl aspartyl glutamate from N-acetyl aspartate at 3 Tesla.
A method is described that allows the in vivo differentiation of N-acetyl aspartate (NAA) from N-acetyl aspartyl glutamate (NAAG) by in vivo MR spectroscopy (MRS) at 3 Tesla (3T). The method, which is based on MEGA-point-resolved spectroscopy (PRESS) editing, selectively targets the aspartyl spin system of one species while deliberately removing the other species from the spectrum. This allows ...
متن کاملBiomechanical factors and physical examination findings in osteoarthritis of the knee: associations with tissue abnormalities assessed by conventional radiography and high-resolution 3 T magnetic resonance imaging
Biomechanical factors and physical examination findings in osteoarthritis of the knee: associations with tissue abnormalities assessed by conventional radiography and high-resolution 3 T magnetic resonance imaging Abstract Introduction. We aimed to explore the associations between knee osteoarthritis (OA)-related tissue abnormalities assessed by conventional radiography (CR) and high resolution...
متن کاملDrug eluting coronary stent: in vitro evaluation of magnet resonance safety at 3 Tesla.
PURPOSE To evaluate MR safety at 3 Tesla for a drug eluting coronary stent. METHODS A drug eluting coronary stent (Endeavor, cobalt alloy, Medtronic Vascular, Santa Rosa, CA) was evaluated for magnetic field interactions, heating, and artifacts at 3 Tesla. MRI-related heating was assessed with the stent in a gelled saline-filled phantom using a transmit/received RF body coil with a whole body...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of pediatric ophthalmology and strabismus
دوره 55 2 شماره
صفحات -
تاریخ انتشار 2018