Subtractive Inhibition Assay for the Detection of E. coli O157:H7 Using Surface Plasmon Resonance
نویسندگان
چکیده
A surface plasmon resonance (SPR) immunosensor was developed for the detection of E. coli O157:H7 by means of a new subtractive inhibition assay. In the subtractive inhibition assay, E. coli O157:H7 cells and goat polyclonal antibodies for E. coli O157:H7 were incubated for a short of time, and then the E. coli O157:H7 cells which bound antibodies were removed by a stepwise centrifugation process. The remaining free unbound antibodies were detected through interaction with rabbit anti-goat IgG polyclonal antibodies immobilized on the sensor chip using a BIAcore 3000 biosensor. The results showed that the signal was inversely correlated with the concentration of E. coli O157:H7 cells in a range from 3.0 × 10(4) to 3.0 × 10(8) cfu/mL with a detection limit of 3.0 × 10(4) cfu/mL. Compared with direct SPR by immobilizing antibodies on the chip surface to capture the bacterial cells and ELISA for E. coli O157:H7 (detection limit: both 3.0 × 10(5) cfu/mL in this paper), the detection limit of subtractive inhibition assay method was reduced by one order of magnitude. The method simplifies bacterial cell detection to protein-protein interaction, which has the potential for providing a practical alternative for the monitoring of E. coli O157:H7 and other pathogens.
منابع مشابه
Monitoring of Escherichia coli O157:H7 in food samples using lectin based surface plasmon resonance biosensor.
A novel surface plasmon resonance (SPR) biosensor using lectin as bioreceptor was developed for the rapid detection of Escherichia coli (E. coli) O157:H7. The selective interaction of lectins with carbohydrate components from bacterial cells surface was used as the recognition principle for the detection. Five types of lectins from Triticum vulgaris, Canavailia ensiformis, Ulex europaeus, Arach...
متن کاملThe Development of a Portable SPR Bioanalyzer for Sensitive Detection of Escherichia coli O157:H7
The purpose of this study was to develop a portable surface plasmon resonance (SPR) bioanalyzer for the sensitive detection of Escherichia coli O157:H7 in comparison with an enzyme-linked immunosorbent assay (ELISA). The experimental setup mainly consisted of an integrated biosensor and a homemade microfluidic cell with a three-way solenoid valve. In order to detect Escherichia coli O157:H7 usi...
متن کاملPCR detection of Escherichia coli O157:H7 directed from slaughtered cattle in Shiraz, Iran
Escheric hia coli O157:H7 lives in the intestines of healthy cattle, and can contaminate meat during slaughtering pr actices . Detection of the low infectious dosage of bacterium requires a sensitive method. We developed polymerase chain reaction (PCR) assays to detect the gene Stx2 irrespective of the bacterial serotype. In this study, the detection limit of the PCR protocol in detecting Stx...
متن کاملModified Vero cell induced by Bifidobacterium bifidum inhibits enterohemorrhagic Escherichia coli O157:H7 cytopathic effect
Enterohemorrhagic Escherichia coli (EHEC), such as E. coli O157:H7, are emerging food-borne pathogens worldwide. This micro-organism can damage the epithelial tissue of the large intestine. The cytotoxic effects can be neutralized by probiotics such as Bifidobacterium bifidum. Probiotics are viable cells that have beneficial effects on the health of the host. The preventing activity of B. bifid...
متن کاملA Rapid Subtractive Immunization Method to Prepare Discriminatory Monoclonal Antibodies for Food E. coli O157:H7 Contamination
To detect food E. coli O157:H7 contamination rapidly and accurately, it is essential to prepare high specific monoclonal antibodies (mAbs) against the pathogen. Cyclophosphamide (Cy)-mediated subtractive immunization strategy was performed in mice to generate mAbs that react with E. coli O157:H7, but not with other affiliated bacteria. Specificity of 19 mAbs was evaluated by ELISA and/or dot-im...
متن کامل