An evaluation of backpack harness systems in non-neutral torso postures.
نویسندگان
چکیده
Much of the research on backpack design has been focused on spinal loading/biomechanics while the wearer is in a neutral/upright trunk posture, such as those employed by outdoor enthusiasts and schoolchildren. This research has led to some important harness design improvements that reduce trunk muscle exertions, fatigue and improve overall comfort. There are number of occupations, however, wherein workers wear back-mounted packs/devices (e.g. air tanks) while working in non-neutral trunk postures. The objective of the current study was to evaluate the effects of these non-neutral postures on biomechanical loading and then reconsider the backpack system design recommendations. Fifteen participants were asked to support a 18.2 kg load on their back while assuming static forward flexed postures of the torso (15 degrees , 30 degrees , 45 degrees , and 60 degrees of sagittal bend). The mass on the back was attached to the participant through two different harness mechanisms: a basic harness design (as seen on college student backpacks) and a more advanced design containing lateral stiffness rods and a weight-bearing hip belt (as seen on backpacks for hikers). While performing these static, posture maintenance tasks, the activation levels of the bilateral trapezius, erector spinae, and rectus abdominis were collected. Participants also provided subjective ratings of comfort. The results showed that there was a significant interaction between harness type and forward flexion angle for the trapezius and the erector spinae muscles. The normalized EMG for the trapezius muscles showed a 14% and 11% reduction in muscle activity at 15 degrees and 30 degrees , respectively, with the advanced design but these positive effects of the advanced design were not found at the greater flexion angles. Likewise the erector spinae muscles showed a 24% and 14% reduction in muscle activity at 15 degrees and 30 degrees , respectively, with the advanced design harness but these effects of the advanced design were not found at the greater forward flexion angles. The level of forward flexion angle affected the rectus abdominis muscle activity, but neither the harness type main effect nor the interaction of harness type and forward flexion angle was significant. The subjective survey results agreed with the EMG results and showed the advanced design harness was generally more comfortable with respect to the shoulder and low back areas. Collectively, the subjective and objective results show a significant improvement with the advanced harness system but also note an interesting interaction with degree of sagittal flexion, indicating a diminished effectiveness of the design improvements at forward flexed postures. Design criteria for harness systems in these forward flexed postures are discussed.
منابع مشابه
Evaluation of Fall Arrest Harness Sizing Schemes
OBJECTIVE This paper evaluated harness sizing schemes and anthropometric criteria for harness design applications. BACKGROUND Updated harness sizing systems are needed to accommodate diverse populations in the current workforce. METHOD Three-dimensional torso scan data and human-harness interfaces from 108 women and 108 men were digitally captured. Abounding box approach was employed to qua...
متن کاملTorso flexion loads and the fatigue failure of human lumbosacral motion segments.
STUDY DESIGN Spine loads associated with lifting a 9-kg weight were estimated at three torso flexion angles (0 degrees, 22.5 degrees, and 45 degrees), and lumbosacral motion segments were cyclically loaded using these loads until failure or to a maximum of 10,020 cycles. OBJECTIVES To simulate the postures and loads experienced by the lumbar spine during repetitive lifting of moderate weights...
متن کاملSagittal plane moment arms of the female lumbar region rectus abdominis in an upright neutral torso posture.
BACKGROUND Prior imaging studies of torso muscle moment arms for use as inputs into biomechanical models have been derived from subjects lying supine. Recent research suggests moment arms of the rectus abdominis are larger when standing versus lying supine. METHODS Axial MRI images, through and parallel to the intervertebral discs were obtained from five females in a standing upright neutral ...
متن کاملDoes Spine Posture Affect Isometric Torso Muscle Endurance Profiles in Adolescent Children?
The purpose of this cross-sectional study was to examine mean values of isometric torso muscle profiles of four spinal postures (good posture, thoracic kyphosis, lumbar lordosis and scoliosis) among 743 children from the ages of 7 to 14 years old. It was hypothesized that having good posture, thoracic hyper-kyphosis, lumbar hyper-lordosis and scoliosis is linked to different isometric torso mus...
متن کاملComparison of human impact response in restraint systems with and without a negative G strap.
A test program to assess the influence of a negative G strap on restraint dynamics and human impact response was conducted at AFAMRL. There were 131 experimental-level impact tests with volunteer subjects performed in eight different test conditions. Forward-facing (-Gx) impacts were carried out on a horizontal accelerator, while vertical (+Gz) impact tests were done on a vertical drop tower fa...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Applied ergonomics
دوره 38 5 شماره
صفحات -
تاریخ انتشار 2007