Laboratory study of selected personal inhalable aerosol samplers.
نویسندگان
چکیده
Assessment of inhalable dust exposure requires reliable sampling methods in order to measure airborne inhalable particles' concentrations. Many inhalable aerosol samplers can be used but their performances widely vary and remain unknown in some cases. The sampling performance of inhalable samplers is strongly dependent on particle size and ambient air velocity. Five inhalable aerosol samplers have been studied in two laboratory wind tunnels using polydisperse glass-beads' test aerosol. Samplers tested were IOM sampler (UK), two versions of CIP 10-I sampler, v1 and v2 (F), 37-mm closed face cassette sampler (USA), 37-mm cassette fitted up with an ACCU-CAP insert (USA), and Button sampler (USA). Particle size-dependent sampling efficiencies were measured in a horizontal wind tunnel under a 1 m s(-1) wind velocity and in a vertical tunnel under calm air, using a specific method with Coulter(R) counter particle size number distribution determinations. Compared with CEN-ISO-ACGIH sampling criteria for inhalable dust, the experimental results show fairly high sampling efficiency for the IOM and CIP 10-I v2 samplers and slightly lower efficiencies for the Button and CIP 10-I v1 samplers. The closed face cassette (4-mm orifice) produced the poorest performances of all the tested samplers. This can be improved by using the ACCU-CAP internal capsule, which prevents inner wall losses inside the cassette. Significant differences between moving air and calm air sampling efficiency were observed for all the studied samplers.
منابع مشابه
A collaborative European study of personal inhalable aerosol sampler performance.
Following the adoption of new international sampling conventions for inhalable, thoracic and respirable aerosol fractions, a working group of Comité Européen de Normalisation (CEN) drafted a standard for the performance of workplace aerosol sampling instruments. The present study was set up to verify the experimental, statistical and mathematical procedures recommended in the draft performance ...
متن کاملPerformance of personal inhalable aerosol samplers in very slowly moving air when facing the aerosol source.
While personal aerosol samplers have been characterized primarily based on wind tunnel tests conducted at relatively high wind speeds, modern indoor occupational environments are usually represented by very slow moving air. Recent surveys suggest that elevated levels of occupational exposure to inhalable airborne particles are typically observed when the worker, operating in the vicinity of the...
متن کاملEvaluation of six inhalable aerosol samplers.
Six inhalable aerosol samplers were evaluated experimentally as area samplers using monodisperse solid particles with aerodynamic diameters ranging from 5 to 68 microm. Sampler performance and inside particle loss at two test wind speeds (0.55 and 1.1 m/sec) and three wind orientations (0, 90, and 180 degrees) were investigated. The six inhalable aerosol samplers tested were a RespiCon, an Inst...
متن کاملResearch Papers Involving the Tsi Respicontm Sampler
Six inhalable aerosol samplers were evaluated experimentally as area samplers using monodisperse solid particles with aerodynamic diameters ranging from 5 to 68 mm. Sampler performance and inside particle loss at two test wind speeds (0.55 and 1.1 m/sec) and three wind orientations (0, 90, and 180 degrees) were investigated. The six inhalable aerosol samplers tested were a RESPICONTM sampler, a...
متن کاملExposure to metalworking fluid aerosols and determinants of exposure.
Metalworking fluid (MWF) aerosols are associated with respiratory disorders including asthma and hypersensitivity pneumonitis. The aims of this study were to describe exposure to inhalable MWF aerosols and volatile compounds in machine shops, to estimate the influence of important determinants of exposure and to compare different sampling techniques for MWF aerosols. Personal full-shift air sam...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Annals of occupational hygiene
دوره 54 2 شماره
صفحات -
تاریخ انتشار 2010