Monochromator for Aberration-Corrected STEM

نویسندگان

  • Masaki Mukai
  • Eiji Okunishi
  • Masanori Ashino
  • Kazuya Omoto
  • Tomohisa Fukuda
  • Akihiro Ikeda
  • Kazunori Somehara
  • Toshikatsu Kaneyama
  • Tomohiro Saitoh
  • Tsukasa Hirayama
  • Yuichi Ikuhara
چکیده

In a scanning transmission electron microscope (STEM), the elemental analysis at atomic resolution is realized by the combination with electron energy-loss spectroscopy (EELS), since an aberration corrected probe forming lens system enables us to obtain an electron probe sized about 0.1 nm [1]. In EELS, the energy resolution is mainly limited by the energy spread of the electron source, which is approximately 0.7 ~ 1.0 eV for a Schottky source and 0.3 ~ 0.5 eV for a cold field emission source. For the analysis of a detailed electronic state at an atomic scale at higher energy resolution, we developed a monochromator for an aberration-corrected STEM, which integrates a double Wien-filter system. [2]

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Present status and future prospects of spherical aberration corrected TEM/STEM for study of nanomaterials∗.

The present status of Cs-corrected TEM/STEM is described from the viewpoint of the observation of nanomaterials. Characteristic features in TEM and STEM are explained using the experimental data obtained by our group and other research groups. Cs correction up to the 3rd-order aberration of an objective lens has already been established and research interest is focused on correcting the 5th-ord...

متن کامل

New possibilities with aberration-corrected electron microscopy.

Unlike light microscopy, where resolution is diffraction limited, the achievable resolution of electron microscopes is limited by lens aberrations so severe that the practical resolution is orders of magnitude worse than the diffraction limit. About 10 years ago, the first practical electron lens spherical aberration correctors were developed, and in the past decade, their performance, versatil...

متن کامل

Monochromated STEM with a 30 meV-wide, atom-sized electron probe.

The origins and the recent accomplishments of aberration correction in scanning transmission electron microscopy (STEM) are reviewed. It is remembered that the successful correction of imaging aberrations of round lenses owes much to the successful correction of spectrum aberrations achieved in electron energy loss spectrometers 2-3 decades earlier. Two noteworthy examples of the types of STEM ...

متن کامل

A monochromatic, aberration-corrected, dual-beam low energy electron microscope.

The monochromatic, aberration-corrected, dual-beam low energy electron microscope (MAD-LEEM) is a novel instrument aimed at imaging of nanostructures and surfaces at sub-nanometer resolution that includes a monochromator, aberration corrector and dual beam illumination. The monochromator reduces the energy spread of the illuminating electron beam, which significantly improves spectroscopic and ...

متن کامل

High-energy-resolution monochromator for aberration-corrected scanning transmission electron microscopy/electron energy-loss spectroscopy.

An all-magnetic monochromator/spectrometer system for sub-30 meV energy-resolution electron energy-loss spectroscopy in the scanning transmission electron microscope is described. It will link the energy being selected by the monochromator to the energy being analysed by the spectrometer, without resorting to decelerating the electron beam. This will allow it to attain spectral energy stability...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014