Interface pressure in transtibial socket during ascent and descent on stairs and its effect on patient satisfaction.
نویسندگان
چکیده
BACKGROUND Transtibial amputees encounter stairs and steps during their daily activities. The excessive pressure between residual limb/socket may reduce the walking capability of transtibial prosthetic users during ascent and descent on stairs. The purposes of the research were to evaluate the interface pressure between Dermo (shuttle lock) and Seal-In X5 (prosthetic valve) interface systems during stair ascent and descent, and to determine their satisfaction effects on users. METHODS Ten amputees with unilateral transtibial amputation participated in the study. Interface pressure was recorded with F-socket transducer (9811E) during stair ascent and descent at self-selected speed. Each participant filled in a questionnaire about satisfaction and problems encountered with the use of the two interface systems. FINDINGS The resultant mean peak pressure (kPa) was significantly lower for the Dermo interface system compared to that of the Seal-In X5 interface system at the anterior, posterior and medial regions during stair ascent (63.14 vs. 80.14, 63.14 vs. 90.44, 49.21 vs. 66.04, respectively) and descent (67.11 vs. 80.41, 64.12 vs. 88.24, 47.33 vs. 65.11, respectively). Significant statistical difference existed between the two interface systems in terms of satisfaction and problems encountered (P<0.05). INTERPRETATION The Dermo interface system caused less pressure within the prosthetic socket compared to the Seal-In X5 interface system during stair negotiation. The qualitative survey also showed that the prosthesis users experienced fewer problems and increased satisfaction with the Dermo interface system.
منابع مشابه
The Effect of Shoe Type and Load Carrying on Electromyographic Activity of Lower Extremity Muscles during Stair Ascent and Descent
Objective Stair ascent and descent is an essential movement task in daily life in which individuals are subjected to repetitive impact forces. The purpose of this study was to evaluate the intensity of Electromyographic (EMG) activity in lower extremity muscles of healthy young men during stair ascent and descent task wearing different type of shoes and carrying loads. Methods Nine men with a ...
متن کاملComparison between microprocessor-controlled ankle/foot and conventional prosthetic feet during stair negotiation in people with unilateral transtibial amputation.
Contrary to stance-phase dorsiflexion of conventional prosthetic feet, the microprocessor-controlled Proprio foot permits swing-phase dorsiflexion on stairs. The purpose of this study was to compare Symmetry in External Work (SEW) between a microprocessor-controlled foot and conventional prosthetic feet in two groups with unilateral transtibial amputation (Medicare Functional Classification Lev...
متن کاملReview of the Socket Design and Interface Pressure Measurement for Transtibial Prosthesis
Socket is an important part of every prosthetic limb as an interface between the residual limb and prosthetic components. Biomechanics of socket-residual limb interface, especially the pressure and force distribution, have effect on patient satisfaction and function. This paper aimed to review and evaluate studies conducted in the last decades on the design of socket, in-socket interface pressu...
متن کاملDynamic interface pressure distributions of two transtibial prosthetic socket concepts.
In this study, we investigated and compared the dynamic interface pressure distribution of hands-off and hands-on transtibial prosthetic systems by means of pressure mapping. Of the 48 established unilateral amputees recruited, half (n = 24) had been wearing pressure-cast prostheses (IceCast Compact) and the other half (n = 24) had been wearing hand-cast sockets of the patellar tendon bearing d...
متن کاملAdvanced Prototyping of Variable Impedance Prosthetic Sockets for Trans-tibial Amputees: Polyjet Matrix 3D Printing of Comfortable Prosthetic Sockets Using Digital Anatomical Data
This work, supported by the Media Lab Consortium, evaluates the design of a Variable Impedance Prosthetic (VIPr) socket for a transtibial amputee using computer-aided design and manufacturing (CAD/CAM). Compliant features are seamlessly integrated into a 3D printed socket to achieve lower interface peak pressures over bony protuberances by using anthropomorphic data acquired through surface sca...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Clinical biomechanics
دوره 28 9-10 شماره
صفحات -
تاریخ انتشار 2013