Assessment of endodontically treated teeth by using different radiographic methods: an ex vivo comparison between CBCT and other radiographic techniques

نویسندگان

  • Kemal Özgür Demiralp
  • Kıvanç Kamburoğlu
  • Kahraman Güngör
  • Selcen Yüksel
  • Gokcen Demiralp
  • Özlem Üçok
چکیده

PURPOSE To compare different radiographic methods for assessing endodontically treated teeth. MATERIALS AND METHODS Root canal treatments were applied in 120 extracted mandibular teeth, which were divided into four groups: (1) ideal root canal treatment (60 teeth), (2) insufficient lateral condensation (20 teeth), (3) root canals filled short of the apex (20 teeth), (4) overfilled root canal treatment (20 teeth). The teeth were imaged using intraoral film, panoramic film, digital intraoral systems (CCD and PSP), CCD obtained with portable X-ray source, digital panoramic, and CBCT images obtained at 0.3 mm(3) and 0.2 mm(3) voxel size. Images were evaluated separately by three observers, twice. Kappa coefficients were calculated. The percentage of correct readings obtained from each modality was calculated and compared using a t-test (p<0.05). RESULTS The intra-observer kappa for each observer ranged between 0.327 and 0.849. The inter-observer kappa for each observer for both readings ranged between 0.312 and 0.749. For the ideal root canal treatment group, CBCT with 0.2 mm(3) voxel images revealed the best results. For insufficient lateral condensation, the best readings were found with periapical film followed by CCD and PSP. The assessment of teeth with root canals filled short of the apex showed the highest percentage of correct readings by CBCT and CCD. For the overfilled canal treatment group, PSP images and conventional periapical film radiographs had the best scores. CONCLUSION CBCT was found to be successful in the assessment of teeth with ideal root canal treatment and teeth with canals filled short of the apex.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ex-vivo Sealing Ability of Different Thicknesses of White and Gray Angelus MTA as an Intra-orifice Barrier in Endodontically Treated Teeth

Introdouction: It is important for the clinician to be aware regarding the necessary thickness of materials used as intra-orifice coronal barriers to prevent microleakage. The purpose of this in vitro study was to compare coronal microleakage of three different thicknesses of white and gray Angelus mineral trioxide aggregate (WAMTA, GAMTA). Materials and methods: A total of 66 canals of extrac...

متن کامل

Diagnostic Accuracy of Different Resolutions of Cone Beam Computed Tomography Imaging System for Detection of Vertical Root Fractures In Presence of Casting Posts

  Objective: The diagnosis of vertical root fracture (VRF) in endodontically treated teeth is a clinical challenge due to lack of specific clinical and radiographic signs. Although radiographic evaluation such as CBCT is helpful, intracanal posts can produce artifacts and may impair the quality of CBCT scans. This study aimed to compare the diagnostic accuracy of different resolutions of CBCT i...

متن کامل

A Comparative Study of Diagnostic Accuracy of Cone Beam Computed Tomography and Intra Oral Digital Radiography Phosphor Storage Plates in Detecting Strip Perforation in Endodontically-Treated Teeth

Background and purpose: Perforation impairs the prognosis of endodontic treatments, so, timely and accurate diagnosis is important. For this purpose, various radiographic diagnostic tools have been studied to select the method that has the least complications and helps in making the most accurate diagnosis. This study aimed to compare the accuracy of cone beam computed tomography (CBCT) and int...

متن کامل

Accuracy of Digital Radiography and Cone Beam Computed Tomography on Periapical Radiolucency Detection in Endodontically Treated Teeth

OBJECTIVES The aim of the present study was to compare the accuracy of intraoral digital periapical radiography and cone beam computed tomography in the detection of periapical radiolucencies in endodontically treated teeth. MATERIAL AND METHODS Radiographic images (cone beam computed tomography [CBCT] scans and digital periapical radiography [PR] images) from 60 patients, achieved from Septe...

متن کامل

Accuracy comparison of CBCT scan and radiography with two different horzental angle in vertical root fracture detection of endodontically treated teeth

Background and Aims: Accurate diagnosis of vertical root fracture (VRF) is a fundamental importance in endodontics. Because of poor prognosis of VRF, digital radiographs with two horizontal angles have limitations in VRF detection. Also, Gutta-percha can produce artifacts that impair CBCT scan accuracy. The aim of this study was to compare accuracy of CBCT and digital radiography system in vert...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 42  شماره 

صفحات  -

تاریخ انتشار 2012